Local anaesthetic techniques and pulsatile ocular blood flow.
نویسندگان
چکیده
AIM To compare pulsatile ocular blood flow (POBF) and intraocular pressure (IOP) between eyes of patients receiving either peribulbar (with and without balloon compression) or subconjunctival local anaesthesia (LA). METHODS 30 eyes of 30 patients undergoing cataract surgery by phacoemulsification were investigated in a study of parallel group design. Ten patients had peribulbar LA and 10 minutes compression with a Honan's balloon (group A). A further 10 patients who received peribulbar LA alone (group B) acted as controls for the effects of balloon compression. Ten other patients were given subconjunctival LA (group C). POBF and IOP were measured using a modified Langham pneumatonometer. Three measurements were made in each eye, the first recording immediately before LA, the second 1 minute after, and the third 10 minutes after LA. RESULTS No significant change in POBF or IOP was recorded in eyes receiving subconjunctival LA. In the peribulbar groups (A and B), there was a drop in median POBF of 252 and 138 microl/min respectively 1 minute after LA, which was statistically significant in both groups (p<0. 01). By 10 minutes, POBF tended to return to baseline levels, but remained significantly reduced in group B (p<0.05). In addition, there was a significant (p<0.05) reduction in IOP (mean drop of 4.82 mm Hg) in group A following peribulbar LA with balloon compression. CONCLUSIONS POBF was significantly reduced after peribulbar LA but was unchanged after subconjunctival LA. Balloon compression reduced IOP and improved POBF following peribulbar LA. The findings may have clinical implications in patients with compromised ocular circulation or significant glaucomatous optic neuropathy.
منابع مشابه
An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...
متن کاملEffect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.
AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...
متن کاملModern Diagnostic Techniques for the Assessment of Ocular Blood Flow in Myopia: Current State of Knowledge
Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow...
متن کاملPULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW
Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...
متن کاملEffect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 84 11 شماره
صفحات -
تاریخ انتشار 2000