Reconstruction of composite in-line electron holograms using a small emission cone.

نویسندگان

  • Roman Holenstein
  • Timothy A Rothwell
  • Mark R A Shegelski
چکیده

We report a new method that gives atomic resolution in the reconstruction of simulated holograms in theoretical low energy electron point source (LEEPS) microscopy, and that uses a screen size that is commensurate with screen sizes used in experimental LEEPS. The method exploits the spherical symmetry in the electron waves emerging from the source. We compare holograms obtained by rotating the screen about an axis passing through the point source as opposed to rotating the atomic cluster in the opposite sense about the same axis. We show that, by generating and combining simulated holograms obtained by rotating the cluster, with the screen held fixed, a composite hologram, comprised of the individual holograms, captures enough information that atomic resolution in the reconstructions is obtained. A key feature is to choose the rotations to optimize the collective interference pattern on the composite hologram. This results in sharper resolution while using a considerably smaller screen size; results are reported for a screen size about ten times smaller than screen sizes typically used in theoretical LEEPS. The method used gives commensurate or better resolution on comparison to results obtained using the larger screen size. Possible implications for experimental LEEPS are briefly discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Iterative Reconstruction with Attenuation Compensation from Cone-Beam Projections Acquired via Nonpl - Nuclear Science, IEEE Transactions on

Single photon emission computed tomography (SPECT) imaging with cone-beam collimators provides improved sensitivity and spatial resolution for imaging small objects with large field-of-view detectors. It is known that Tuy’s cone-beam data sufficiency condition must be met to obtain artifact-free reconstructions. Even though Tuy’s condition was derived for an attenuation-free situation, we hypot...

متن کامل

-

In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...

متن کامل

Tomographic reconstruction of multiple in-line holograms for multiple scattering in low energy electron holography

We generate simulated holograms for low energy electron point source (LEEPS) microscopy. For a given object (atomic cluster) we construct a number of different holograms by varying the position or the orientation of the object relative to the screen. We then compare the three-dimensional structures of the reconstructions obtained from these holograms using methods developed and reported in prev...

متن کامل

Simultaneous reconstruction of phase and amplitude contrast from a single holographic record.

We present a reconstruction technique for simultaneous retrieval of absorption and phase shifting properties of an object recorded by in-line holography. The routine is experimentally tested by applying it to optical holograms of a pure phase respectively a pure amplitude object of micrometer dimensions that has been machined into a glass-plate using a focused ion beam. The method has also been...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 94 2  شماره 

صفحات  -

تاریخ انتشار 2003