An automated interferometer for the analysis of anaesthetic gas mixtures.

نویسندگان

  • B R Sugg
  • E Palayiwa
  • W L Davies
  • R Jackson
  • T McGraghan
  • P Shadbolt
  • S J Weller
  • C E Hahn
چکیده

A microprocessor-controlled interferometer is described. The eyepiece of a conventional Jamin type interferometer has been replaced by an array of photocells which records the intensity across the interference pattern. Mathematical correlation procedures are used to locate the principal interference pattern maximum and, by sequential analysis of a fresh gas mixture followed by fresh gas plus vapour, it is possible to determine both oxygen and vapour concentrations. The instrument was used to analyse mixtures of oxygen and nitrous oxide and also oxygen, nitrous oxide plus halothane. It was found that the oxygen concentration could be determined to an accuracy of +/- 1% v/v and the vapour concentration to +/- 0.1% v/v. The instrument is suitable for monitoring concentrations delivered by an anaesthetic machine and may be included in a microprocessor-controlled anaesthetic machine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation of Aromatic and Alcoholic Mixtures using Novel MWCNT-Silica Gel Nanocomposite as an Adsorbent in Gas Chromatography

The separations of alcohols with hydrophilic and hydrophobic parts, and the separation of aromatic mixtures, are extremely important processes in gas and petroleum industries. Choosing an adsorbent for performing this separation is the most important part of the process. Silica gel is used as an adsorbent is various techniques such as pressure swing adsorption (PSA) and gas and liquid chromatog...

متن کامل

Automated control of end-tidal inhalation anaesthetic concentration using the GE Aisys CarestationTM†

Editor’s key points † New anaesthetic machines can automatically control the concentrations of volatile agents and fresh gas flow. † This study compared the ETControlTM with manual adjustment of fresh gas flow by the anaesthetist in clinical practice. † Time spent at low gas flows was significantly greater and volatile agent usage and costs were lower when using the automated system. † Further ...

متن کامل

P110: Nitrous Oxide and Neuroinflammation

Nitrous oxide was an anaesthetic gas that was used for many years. There were many anaesthetic drugs in operations  with many side effects. Nitrous oxide had some side effects too. But it was a safe gas in many times. In hospital personnel who worked in operating rooms exposure to this gas was important. The objective of this study was the introduction of nitrous oxide and neurologic side ...

متن کامل

Adsorption of halothane vapour in glass syringes.

THE ~-'v~OST COM~ON too1 in medical research is the glass syringe. It is often employed for the sampling of various gases, vapours, and their mixtures, During our experiments regarding reproducibility of anaesthetic vapour-gas mixtures, we found that the results depended considerably upon the time the mixture remained in the syringe before analysis. After considering and eliminating other possi...

متن کامل

Predicting the Liquid Density of Gas Condensates and LNG Mixtures from Equations of State

In this contribution, two approaches are followed to predict the saturated liquid density of liquefied natural gas (LNG) mixtures. In one approach, 12 cubic equations of state (EoSs), comprising the popular Peng-Robinson (PR) and Redlich-Kwong-Soave (RKS), are employed to predict the saturated liquid density of 20 LNG mixtures. In the other approach, these EoS are used in conjunction with a rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 1988