A New Determination Method of the Solubility Parameter of Polymer Based on AIE.
نویسندگان
چکیده
An accurate method of the fluorescence probe approach based on an aggregation-induced emission (AIE) molecule (tetraphenylethylene) for measuring the solubility parameter of the polymer is reported. This method is distinctive in that the approach can make the polymer chain conformation in solution be related to the fluorescence intensity. Since the solubility parameter of the polymer is also closely linked to its chain conformation in solution, the solubility parameter can be determined by the fluorescence intensity. The range of the solubility parameter of polymethyl methacrylate (PMMA) tested by this method was from 9.00 cal1/2cm-3/2 to 10.00 cal1/2cm-3/2. The results are more accurate than those obtained from the traditional turbidimetric titration method, ranging from 8.60 cal1/2cm-3/2 to 12.15 cal1/2cm-3/2. According to the photoluminescence (PL) intensities spectra, the solubility parameters of PMMA and polyvinyl acetate (PVAc) are 9.19 cal1/2cm-3/2 and 9.85 cal1/2cm-3/2, respectively.
منابع مشابه
Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate
In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...
متن کاملPredicting Solubility of Isotactic Poly (1-Butene) in Different Organic Solvents by Modified UNIQUAC
The UNIQUAC activity coefficient model is extended to predict solid-liquid equilibrium of isotactic crystalline poly (1-butene), iPBu-1, in different organic solvents. The UNIQUAC activity coefficient model used in this work is based on the concept of group contribution and consists of combinatorial, residual and free volume terms. To account for branching of atom groups in the monomer structur...
متن کاملA New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer
Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...
متن کاملImpact of Measuring Devices and Data Analysis on the Determination of Gas Membrane Properties
The time-lag method, using a gas permeation experiment, is currently the most popular method for determining the membrane properties: diffusivity coefcient and permeability coefcient, and from which the solubility coefcient can be calculated. In this investigation, the impact of systematic, random (noise), resolution and extrapolation errors associated with gas permeatio...
متن کاملA New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer
Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Molecules
دوره 22 1 شماره
صفحات -
تاریخ انتشار 2016