Evaluation of inhaler handling-errors, inhaler perception and preference with Spiromax, Easyhaler and Turbuhaler devices among healthy Finnish volunteers: a single site, single visit crossover study (Finhaler).

نویسندگان

  • Niklas Sandler
  • Jenny Holländer
  • Disa Långström
  • Pekka Santtila
  • Anni Saukkonen
  • Saku Torvinen
چکیده

INTRODUCTION Correct inhaler technique and device preference are positively correlated with improved adherence and clinical outcomes. This study was designed to investigate inhaler technique mastery and device preference for three different dry powder inhalers, Spiromax, Easyhaler and Turbuhaler. METHODS This was a single site, single visit, crossover study assessing device mastery, handling errors and preference using empty Spiromax, Easyhaler and Turbuhaler devices in healthy adult Finnish volunteers. Inhaler naïve adult participants were observed by healthcare professionals (HCPs) to evaluate the proportion of participants achieving device mastery (defined as an absence of HCP observed errors) using a three-step approach: (1) intuitive use (with no instructions), (2) after reading the patient information leaflet and (3) after HCP instruction. HCPs monitored and recorded errors based on device-specific handling error checklists. At the end of the study, participants completed a device preference questionnaire and rated their satisfaction with the three devices. RESULTS Spiromax was correctly used by 37.5% and 93.3% of participants in steps 1 and 2, respectively, compared with 0% and 58.3% with Easyhaler, and 9.2% and 76.7% with Turbuhaler. All three devices showed high mastery (>95%) in step 3. The most common error reported with Spiromax was related to the orientation of the device. Not shaking the device was the most common error with Easyhaler. Errors in priming the device were the most common with Turbuhaler. Spiromax, Easyhaler and Turbuhaler were rated as the 'easiest device to use' by 73.1%, 12.6% and 14.3% of participants, respectively. The HCP instructions clearly improved the use of all devices. CONCLUSION Higher levels of device mastery, including intuitive/ease of use, were reported by naïve users when using Spiromax compared with Easyhaler and Turbuhaler.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Inhaler Technique Mastery and Handling Errors With Spiromax®, Easyhaler®, And Turbuhaler® Devices (Finhaler).

 During Step 2 (after reading the PIL), the percentages of participants who used the device without error were higher with Spiromax® (93.3%) compared with Easyhaler® (58.3%), or Turbuhaler® (76.7%) (Table 1). This difference was significant for all comparator groups (p<0.001 [Spiromax® vs Easyhaler® and Spiromax® vs Turbuhaler®]; Table 1).  Similarly, in Step 1, Spiromax® was associated with ...

متن کامل

[Patient preference in the choice of dry powder inhalers].

OBJECTIVE To investigate a group of patients' preferences among 3 dry powder inhalers--Accuhaler, Easyhaler, and Turbuhaler--and to analyze the features that were most important for motivating choices. MATERIAL AND METHOD The study enrolled 30 patients with stable asthma with a mean (SD) age of 40 (13) and who habitually used inhaled corticosteroids. The patients were shown in detail how to u...

متن کامل

Inhalation characteristics of asthma patients, COPD patients and healthy volunteers with the Spiromax® and Turbuhaler® devices: a randomised, cross-over study

BACKGROUND Spiromax® is a novel dry-powder inhaler containing formulations of budesonide plus formoterol (BF). The device is intended to provide dose equivalence with enhanced user-friendliness compared to BF Turbuhaler® in asthma and chronic obstructive pulmonary disease (COPD). The present study was performed to compare inhalation parameters with empty versions of the two devices, and to inve...

متن کامل

A randomized, double-blinded, double-dummy efficacy and safety study of budesonide-formoterol Spiromax® compared to budesonide-formoterol Turbuhaler® in adults and adolescents with persistent asthma.

BACKGROUND Budesonide and formoterol (BF) Spiromax® is a dry powder inhaler designed to deliver BF with maximum ease of use for patients with asthma or chronic obstructive pulmonary disease. METHODS A phase 3b, 12-week, multicenter, double-blind, double-dummy, randomized, controlled trial in patients (≥12 years) with persistent asthma. PRIMARY OBJECTIVE to demonstrate non-inferiority of twi...

متن کامل

Spiromax, a New Dry Powder Inhaler: Dose Consistency under Simulated Real-World Conditions

BACKGROUND Spiromax(®) is a novel dry powder inhaler for patients with asthma or chronic obstructive pulmonary disease (COPD). The studies presented here provide further data on attributes (in vitro dosing consistency with budesonide-formoterol (DuoResp) Spiromax; flow rates through empty versions of the Spiromax and Turbuhaler inhaler) of importance to patients with asthma or COPD. METHODS D...