Hemodynamic effects of direct biventricular compression studied in isovolumic and ejecting isolated canine hearts.
نویسندگان
چکیده
BACKGROUND Biventricular direct cardiac compression (DCC) can potentially support the failing heart without the complications associated with a blood/device interface. The effect of uniform DCC on left and right ventricular performance was evaluated in 7 isolated canine heart preparations. METHODS AND RESULTS A computer-controlled afterload system either constrained the isolated heart to contract isovolumically or simulated hemodynamic properties of physiological ejection. Biventricular DCC was provided by a chamber surrounding the heart that allowed adjustment of the compression pressure, onset time, and duration. Through a series of ventricular preloads, the effect of DCC on the end-systolic pressure-volume relationship (ESPVR) was evaluated under isovolumic and ejecting conditions. Under both conditions, DCC shifted the ESPVR of the left and right ventricles upward by an amount approximately equal to the compression pressure. The augmentation of end-systolic pressure for each initial preload tested, however, was less under ejecting conditions, because reductions in end-systolic and end-diastolic volumes occurred with ejection. Nevertheless, the net effect was to increase stroke volume. Measurement of M&f1;O2 demonstrated that at a given ventricular volume, M&f1;O2 did not change with DCC; however, peak ventricular pressure increased substantially, so that the effective pressure-volume area increased. CONCLUSIONS Biventricular DCC can augment end-systolic pressure with no added costs of M&f1;O2. Under ejecting conditions, this augmentation of ventricular contracting ability manifests as increases in stroke volume. Thus, DCC represents a feasible alternative form of ventricular assist, and devices that support the heart in this manner should be further explored.
منابع مشابه
Hemodynamic determinants of the time-course of fall in canine left ventricular pressure.
The hemodynamic determinants of the time-course of fall in isovolumic left ventricular pressure were assessed in isolated canine left ventricular preparations. Pressure fall was studied in isovolumic beats or during prolonged isovolumic diastole after ejection. Pressure fall was studied in isovolumic relaxation for isovolumic and ejecting beats (r less than or equal to 0.98) and was therefore c...
متن کاملEnd-systolic pressure as a balance between opposing effects of ejection.
Ejection has previously been thought to exert only negative effects on end-systolic left ventricular pressure, via mechanisms like shortening deactivation and the force-velocity relation. Whether ejection also exerted a positive influence on pressure generation was tested by comparing two successive beats: 1) the last beat of steady-state ejection versus 2) a totally isovolumic contraction at t...
متن کاملEqual oxygen consumption rates of isovolumic and ejecting contractions with equal systolic pressure-volume areas in canine left ventricle.
Left ventricle systolic pressure-volume area (PVA) has been found to be highly linearly correlated with cardiac oxygen consumption rate per beat (VO2) in a given canine heart with a stable inotropic background. PVA is a specific area in the pressure-volume (P-V) diagram that is bounded by the end-systolic and end-diastolic P-V relationship lines and the systolic segment of the P-V loop, consist...
متن کاملLong-term versus intrabeat history of ejection as determinants of canine ventricular end-systolic pressure.
We studied the effect of ejection on end-systolic pressure in isolated heart preparations. Ejecting beats were compared with isovolumic beats having the same volume as at end systole. While holding end-systolic volume constant, various stroke volumes, including negative stroke volumes (volume injected during systole), were imposed using a predetermined volume command. After switching contractio...
متن کاملEffects of afterload on regional left ventricular torsion.
OBJECTIVE To determine if left ventricular torsion, as measured by magnetic resonance tissue tagging, is afterload dependent in a canine isolated heart model in which neurohumoral responses are absent, and preload is constant. METHODS In ten isolated, blood perfused, ejecting, canine hearts, three afterloads were studied, while keeping preload constant: low afterload, high afterload (stroke v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 99 16 شماره
صفحات -
تاریخ انتشار 1999