Depth measurement with the slit-lamp microscope.

نویسنده

  • E S Perkins
چکیده

The sagittal distance of ocular structures can be obtained with a slit-lamp microscope providing the movement of the slit-lamp can be measured. A simple device consisting of a pointer attached by a spring clip to the axle of a Haag-Streit 900 slit-lamp is described. The pointer rides over a scale which slides with the slit-lamp. Comparisons of anterior chamber depth and lens thickness showed a high correlation between this optical method and ultrasound measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Slit-lamp measurement of the anterior chamber depth.

A technique is proposed which allows assessment of the anterior chamber depth with a standard table slit-lamp without any extra attachments. A final approximation is made which suggests that a 1 degree change in the angle between the observation and illumination systems of the slit lamp when the end point is reached indicates a change in anterior chamber depth of 0.1 mm.

متن کامل

Use of Fourier-Domain Optical Coherence Tomography to Evaluate Anterior Stromal Opacities in Donor Corneas

Purpose. To evaluate Fourier-domain optical coherence tomography (FD-OCT) as an adjunct to traditional slit lamp examination of donor corneas with suspected Anterior Stromal Opacities. Methods. Seven corneas suspected of having anterior stromal opacities by slit lamp examination were evaluated with FD-OCT. Each cornea was evaluated to confirm the presence of opacity and, if present, the depth o...

متن کامل

Use of a slit-lamp microscope for treating impacted facial foreign bodies in the emergency department

Identifying, locating, diagnosing, and treating small foreign bodies (FBs) in soft tissues is a challenge for emergency physicians in the emergency department. Additionally, potential complications owing to the remnant FBs are medico-legally significant. The efficacy of conventional imaging methods such as radiography, computed tomography, and ultrasonography are largely limited in visualizing ...

متن کامل

Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry

BACKGROUND The purpose of this study was to evaluate the precision of intraocular pressure measurements obtained by PT100 noncontact tonometry in a handheld and slit lamp-mounted position in comparison with that of Goldmann applanation tonometry in healthy young adults. METHODS Sixty eyes from 60 subjects (30 men and 30 women) aged 22 ± 1 (range 20-24) years participated in this study. Tripli...

متن کامل

A new method of estimating the depth of the anterior chamber.

A new method of estimating the depth of the anterior chamber with an accuracy of approximately 0-1 mm is described. The estimate is made with a conventional Haag-Streit 900 slit lamp without any extra attachments.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 72 5  شماره 

صفحات  -

تاریخ انتشار 1988