Corrosion of orthodontic temporary anchorage devices.
نویسندگان
چکیده
Corrosion of orthodontic miniscrews or temporary anchorage devices (TADs) has been proposed as a contributor to inflammation, which in turn is a factor in the clinical success of miniscrews. The purpose of this study was to measure the electrochemical properties of orthodontic miniscrews in artificial saliva with and without fluoride. The corrosion properties of three miniscrew products (VectorTAS, Ormco Corp.; Unitek TAD, 3M Unitek; and Through-Hole Screw, American Orthodontics) were tested in an artificial saliva (Fusayama-Meyer) with (1500 ppm) or without fluoride (n = 10/product/solution). Open circuit potential (OCP), polarization resistance (R p), and corrosion current (I corr) were measured and statistically analysed with the Friedman/Tukey least significant difference tests. No significant differences (P > 0.05) between miniscrews with regard to OCP, R p, and I corr were found except that the American Orthodontics miniscrews had a significantly (P < 0.05) more noble OCP compared to the others. Incorporation of 1500 ppm fluoride in the artificial saliva significantly (P < 0.001) lowered the OCP, reduced the polarization resistance, and increased the corrosion current of each miniscrew product. Few differences existed in the electrochemical properties of miniscrews from the three different manufacturers; however, exposure to fluoride was detrimental to the corrosion properties of all miniscrews.
منابع مشابه
Use of miniplates as a method for orthodontic anchorage: a case report
Introduction: Temporary anchorage devices (TADs) have been developed to be used as direct adjuncts in orthodontic treatment and have facilitated treatment of more complex orthodontic cases, including patients with dental impaction. Objectives: This clinical case reports the applicability of TADs in the orthodontic treatment of a patient with impacted mandibular second molars. Surgical and or...
متن کاملSecond Molar Uprighting with Temporary Anchorage Devices: A Finite Element Study
BACKGROUND AND OBJECTIVE: Premature loss of mandibular first molar is a common problem in adults. Mesial tipping of second molar may occur in this situation. Various orthodontic mechanics have been proposed for molar uprighting. The aim of this study was to compare four methods of molar uprighting using Finite Element Analysis(FEM). METHODS: In first model of this finite element study, a 0.019...
متن کاملSurgical management of fractured orthodontic mini- implant- a case report.
The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes su...
متن کاملExperience with orthodontic temporary anchorage devices
In orthodontics, anchorage is a prerequisite for the application of therapeutic forces and can limit their successful use. According to the intended treatment goals, desired tooth movements should, therefore, be maximized and undesirable effects minimized. But additional anchorage such as extraand intraoral forces are visible and hence compliance dependent and are associated with the risk of un...
متن کاملMiniscrew implants as temporary anchorage devices in orthodontics: a comprehensive review.
In recent times, the use of miniscrew implants to obtain absolute anchorage has gained momentum in clinical orthodontics as rigid anchorage modality. Miniscrew implants offers many advantages when used as temporary anchorage devices like, easy placement and removal, immediate loading, can be used in a variety of locations, provide absolute anchorage, economic and requires less patient cooperati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of orthodontics
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2013