Comparison of Changes in Intraocular Pressure and Anterior Chamber Before and After Cataract Surgery

نویسنده

  • Roland Lee
چکیده

Cataract is the leading cause of blindness worldwide. Fortunately, cataract-induced blindness is reversible by cataract surgery. In addition to reclaiming lost vision, cataract surgery lowers intraocular pressure, but the reason for this remains unclear. Understanding the mechanism behind intraocular pressure reduction following cataract surgery has implication for treating glaucoma, which involves lowering intraocular pressure through glaucoma medications or surgeries. Adequate control of intraocular pressure through cataract surgery would render glaucoma treatment nonessential and could become an optimal solution for patients with coexisting cataract and glaucoma. To answer the research question of whether anterior chamber angle alteration induces intraocular pressure reduction, we compared changes in intraocular pressure and anterior angle before and after cataract surgery. Age, ethnicity, and gender are risk factors related to cataract development, but their effects on the degree of changes in intraocular pressure and anterior chamber angle following cataract surgery are unclear. The degree of change in intraocular pressure and anterior chamber angle following cataract surgery is evaluated in terms of these risk factors, to assess whether a relationship exist between them. Statistical analysis revealed a significant decrease in intraocular pressure and an increase in anterior chamber angle opening distance following cataract surgery. However, comparison of the degree of changes in intraocular pressure and angle opening distance in terms of age, ethnicity, and gender revealed insignificant difference within each group. In conclusion, we found that anterior chamber angle extension is a mechanism for intraocular pressure reduction following cataract surgery and this is consistent regardless of age, gender, and ethnicity. Repeated studies with this experimental design at other clinical sites are needed to substantiate the applicability of our findings to the general population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy

Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...

متن کامل

The Effect of Phacoemulsification with Posterior Chamber Intraocular Lens Implantation on Intraocular Pressure and Anterior Chamber Depth

Purpose: To evaluate intraocular pressure (IOP) and anterior chamber depth (ACD) change after phacoemulsification with posterior chamber intraocular lens implantation Methods: In this quasi-experimental study, 84 patients with senile cataract were included. All patients had normal IOP. Patients with traumatic and complicated cataract, any history of uveitis, glaucoma, or other ocular disease or...

متن کامل

The effect of low dose of ketamine on intraocular pressure in patients undergoing cataract surgery

Background: Cataract surgery is one of the most common surgeries in the world, especially in elderly patients, and often performed topically with sedative agents. Ketamine is one of the most commonly used agents and the effect of different doses on intraocular pressure is in dispute. The present study investigates the effect of a low dose of ketamine on intraocular pressure in patients undergoi...

متن کامل

Evaluation of ultrasonic biomicroscopy results in anterior eye segment before and after cataract surgery

BACKGROUND The aim of this study was to assess the value of ultrasonic biomicroscopy in reporting decreases in intraocular pressure resulting from changes in anterior chamber depth and angle after phacoemulsification and intracapsular lens implantation in patients with cataract. METHODS This prospective interventional case series included 50 eyes of 50 consecutive subjects operated at the sam...

متن کامل

The effect of oral clonidine pretreatment on intraocular pressure and hemodynamic stability after succinylcholine injection and intubation in cataract surgery

 Abstract Background: Providing better surgical conditions with meticulous control of Intraocular Pressure (IOP) is one of the most important factors that affect the success rate in ophthalmic surgery. Clonidine is a selective central α2 agonist with analgesic, antianxiety and sedative effects which makes it a good choice in premedication recently. In this study, we compared the effects of oral...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010