Study on the Effect of Object to Camera Distance on Polynomial Expansion Coefficients in Barrel Distortion Correction

نویسندگان

  • Hui Tian
  • Thambipillai Srikanthan
  • Vijayan K. Asari
  • Siew Kei Lam
چکیده

Videoendoscopy is becoming increasingly popular in surgical procedures. Wide-angle lenses are commonly employed in such applications for enhanced viewing capability. However, images captured with these lenses suffer from barrel distortion. 2D distortion correction for images captured with wide-angle lenses has been widely investigated. In clinical applications, it is necessary to incorporate correction techniques that are independent of the distance from the object to the camera lens. In this paper, we prove that for a wide-angle camera lens with fixed focal length, the distortion correction coefficients remain the same for distances within the minimum and maximum range (depth of field). Experiments have also been performed to verify this.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Vlsi Approach for Distortion Correction in Surveillance Camera Images

An efficient VLSI architecture implementation for barrel distortion correction in surveillance camera images is presented. The distortion correction model is based on least squares estimation method. To reduce the computing complexity, an odd-order polynomial to approximate the back-mapping expansion polynomial is used. By algebraic transformation, the approximated polynomial becomes a monomial...

متن کامل

Nonlinear Distortion Correction in Endoscopic Video Images

Modern video-based endoscopes offer physicians a wide-angle field of view for minimally-invasive procedures. Unfortunately, inherent barrel distortion prevents accurate perception of range. This makes measurement and distance judgment difficult and causes difficulties in emerging applications, such as 3D medical-image registration. Such distortion also arises in other wide field-of-view camera ...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Evaluation and Comparison of Topographic Correction Models Is Applied on the Series Landsat Images Using Spectrometery Data

The effect of topography on the radiance record in satellite image, probably reduce the accuracy of algorithem impliementation on the images . Therefore, to reduce the effect of topography, various correction models based on interaction between light and object needs to be defined. This research introduces lombertin correction model (Cosine model) and non_lombertin correction model (mineart and...

متن کامل

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002