Aortic valve resistance as an adjunct to the Gorlin formula in assessing the severity of aortic stenosis in symptomatic patients.
نویسندگان
چکیده
OBJECTIVES This study was conducted to determine the utility of aortic valve resistance in assessing the severity of aortic stenosis. BACKGROUND Assessment of the severity of aortic stenosis has traditionally employed hemodynamic data and the Gorlin formula to calculate the area of the aortic valve. Recently, flow dependence of the Gorlin formula has been identified and the accuracy of the formula challenged. Aortic valve resistance, the quotient of gradient and cardiac output, has been advanced as potentially useful in assessing the severity of valve stenosis. METHODS We studied 48 symptomatic patients with an initial diagnosis of severe aortic stenosis based on a calculated aortic valve area of less than or equal to 0.8 cm2 by the Gorlin formula. Forty of these patients (Group I) were confirmed to have severe aortic stenosis, whereas 8 (Group II) were subsequently proved not to have severe aortic stenosis. The 18 patients in Group I with a valve area of 0.6 to 0.8 cm2 (Group IA) were directly compared with Group II patients who had a similar valve area. RESULTS Aortic valve area was nearly identical in Group IA and Group II patients (0.69 +/- 0.05 and 0.71 +/- 0.06 cm2, respectively, p = NS). However, aortic valve resistance was much less in Group II patients (212 +/- 6 vs. 316 +/- 11 dynes.s.cm-5, p less than 0.0001). In this small cohort, aortic valve resistance achieved nearly complete separation of patients in Groups IA and II. CONCLUSIONS In some patients with relatively mild aortic stenosis, the calculated valve area may indicate that the stenosis is severe. The use of aortic valve resistance in conjunction with the Gorlin formula helps separate patients with truly severe aortic stenosis from those with milder disease.
منابع مشابه
Comparison of Doppler echocardiographic methods with heart catheterisation in assessing aortic valve area in 100 patients with aortic stenosis.
OBJECTIVE To examine the practicability and accuracy of Doppler echocardiographic methods in determining aortic valve area. METHODS Aortic valve areas determined by three methods using Doppler echocardiography (applying the continuity equation and the modified Gorlin formula using data from Doppler echocardiography and right heart catheterisation) were compared with values obtained by heart c...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملA simplified valve formula for the calculation of stenotic cardiac valve areas.
We have simplified the Gorlin formula and have compared our measurements of the aortic or mitral valve area, using the original Gorlin formula and the simplified valve formula in 100 consecutive patients. The valve area was measured by the simplified formula as cardiac output (l/min) divided by the square root of pressure differences across the valve. In patients with aortic stenosis of varying...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملEffects of increasing flow rate on aortic stenotic indices: evidence from percutaneous transvenous balloon dilatation of the mitral valve in patients with combined aortic and mitral stenosis.
OBJECTIVES To investigate the effects of transvalvar flow rate on aortic valve resistance and valve area after percutaneous transvenous balloon dilatation of the mitral valve in a homogeneous group of patients with rheumatic heart disease. DESIGN Retrospective analysis of 12 patients with combined aortic and mitral stenosis who had undergone balloon dilatation of the mitral valve over a perio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 20 7 شماره
صفحات -
تاریخ انتشار 1992