Fabrication and use of nanometer-sized electrodes in electrochemistry.

نویسندگان

  • R M Penner
  • M J Heben
  • T L Longin
  • N S Lewis
چکیده

Electrodes with electrochemical dimensions as small as 10 angstroms have been fabricated and used for electrochemical studies. These nanometer-scale electrodes have enabled the measurement of electron-transfer rate constants, k(het), that are two orders of magnitude faster than k(het) values accessible with any other electrochemical method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tunable nanometer electrode gaps by MeV ion irradiation.

We report the use of MeV ion-irradiation-induced plastic deformation of amorphous materials to fabricate electrodes with nanometer-sized gaps. Plastic deformation of the amorphous metal Pd(80)Si(20) is induced by 4.64 MeV O(2+) ion irradiation, allowing the complete closing of a sub-micrometer gap. We measure the evolving gap size in situ by monitoring the field emission current-voltage (I-V) c...

متن کامل

Fabrication and Characterization of Graphene Electrodes for Electrochemistry Experiments

The goal of our project is to pattern well-defined electrodes from single-layer graphene for use in electrochemistry investigations. We have fabricated devices using both mechanically exfoliated graphene and chemical vapor deposition (CVD) graphene. Preliminary experimental data show that the graphene is chemically clean, based on measurements that the effective area of the electrodes determine...

متن کامل

Fabrication of gradient polymer surfaces using bipolar electrochemistry

This report focuses on recent developments using bipolar electrochemistry as an effective tool for the fabrication of gradient polymer surfaces. The electrochemical doping and reactions of conducting polymers under an applied potential distribution using bipolar electrodes have been carried out to prepare conducting polymers with composition gradients. Indirect electrolysis using an electrogene...

متن کامل

Observation of nanometer-sized electro-active defects in insulating layers by fluorescence microscopy and electrochemistry.

We report a method to study electro-active defects in passivated electrodes. This method couples fluorescence microscopy and electrochemistry to localize and size electro-active defects. The method was validated by comparison with a scanning probe technique, scanning electrochemical microscopy. We used our method for studying electro-active defects in thin TiO2 layers electrodeposited on 25 μm ...

متن کامل

Fabrication and characterization of nanopore-based electrodes with radii down to 2 nm.

We report on the fabrication and characterization of gold nanoelectrodes with carefully controlled nanometer dimensions in a matrix of insulating silicon nitride. A focused electron beam was employed to drill nanopores in a thin silicon nitride membrane. The size and shape of the nanopores were studied with high-resolution transmission electron microscopy and electron-energy-loss two-dimensiona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Science

دوره 250 4984  شماره 

صفحات  -

تاریخ انتشار 1990