Automated grading for diabetic retinopathy: a large-scale audit using arbitration by clinical experts.

نویسندگان

  • Alan D Fleming
  • Keith A Goatman
  • Sam Philip
  • Gordon J Prescott
  • Peter F Sharp
  • John A Olson
چکیده

BACKGROUND/AIMS Automated grading software has the potential to reduce the manual grading workload within diabetic retinopathy screening programmes. This audit was undertaken at the request of Scotland's National Diabetic Retinopathy Screening Collaborative to assess whether the introduction of automated grading software into the national screening programme would be safe, robust and effective. METHODS Automated grading, performed by software for image quality assessment and for microaneurysm/dot haemorrhage detection, was carried out on 78,601 images, obtained from 33,535 consecutive patients, which had been manually graded at one of two regional diabetic retinopathy screening programmes. Cases where the automated grading software assessment indicated gradable images with no disease but the screening programme indicated ungradable images or disease more severe than mild retinopathy were arbitrated by seven senior ophthalmologists. RESULTS 100% (180/180) of patients with proliferative retinopathy, 100% (324/324) with referable background retinopathy, 100% (193/193) with observable background retinopathy, 97.3% (1099/1130) with referable maculopathy, 99.2% (384/387) with observable maculopathy and 99.8% (1824/1827) with ungradable images were detected by the software. CONCLUSION The automated grading software operated to previously published results when applied to a large, unselected population attending two regional screening programmes. Manual grading workload reduction would be 36.3%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Automated Disease Detection in Diabetic Retinopathy Screening Using Two-Field Photography

AIM To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. METHODS Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of ...

متن کامل

Validation of automated screening for referable diabetic retinopathy with the IDx‐DR device in the Hoorn Diabetes Care System

PURPOSE To increase the efficiency of retinal image grading, algorithms for automated grading have been developed, such as the IDx-DR 2.0 device. We aimed to determine the ability of this device, incorporated in clinical work flow, to detect retinopathy in persons with type 2 diabetes. METHODS Retinal images of persons treated by the Hoorn Diabetes Care System (DCS) were graded by the IDx-DR ...

متن کامل

The evidence for automated grading in diabetic retinopathy screening.

Systematic screening for diabetic retinopathy using retinal photography has been shown to reduce the incidence of blindness among people with diabetes. The implementation of diabetic retinopathy screening programmes faces several challenges. Consequently, methods for improving the efficiency of screening are being sought, one of which is the automation of image grading involving detection of im...

متن کامل

The role of haemorrhage and exudate detection in automated grading of diabetic retinopathy.

BACKGROUND/AIMS Automated grading has the potential to improve the efficiency of diabetic retinopathy screening services. While disease/no disease grading can be performed using only microaneurysm detection and image-quality assessment, automated recognition of other types of lesions may be advantageous. This study investigated whether inclusion of automated recognition of exudates and haemorrh...

متن کامل

Automated detection of fundus photographic red lesions in diabetic retinopathy.

PURPOSE To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. METHODS Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 94 12  شماره 

صفحات  -

تاریخ انتشار 2010