On chromium direct ETAAS determination in serum and urine
نویسندگان
چکیده
A simple, accurate and reliable method for direct electrothermal atomic absorption spectrometric (ETAAS) determination of chromium in serum and urine samples without any preliminary sample pretreatment is described. Instrumental parameters are optimized in order to define: the most suitable atomizer, optimal temperature program and efficient modifier. An appropriate quantification method is proposed taking into account a matrix interference study. Pyrocoated graphite tubes and wall atomization, pretreatment temperature of 700 ◦C, atomization temperature of 2600 ◦C, hydrogen peroxide as modifier and standard addition calibration are recommended. The accuracy of the method proposed for Cr determination in serum and urine was confirmed by comparative analysis of parallel samples after wet or dry ashing as well as by the analysis of two certified reference materials: Serum, Clin Rep 1 and Lypochek Urine, level 1. The detection and determination limits achieved for both matrices are 0.08 μg/L and 0.15 μg/ L respectively. The relative standard deviation varied between 15 and 18 % for the chromium content in the samples in the range 0.08-0.2 μg/L and between 4 and 7 % for the chromium content in the range 0.2-2.0 μg /L for both matrices. c © Versita Warsaw and Springer-Verlag Berlin Heidelberg. All rights reserved.
منابع مشابه
Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملDetermination of hexavalent chromium in aqueous and alkaline soil extracts
A fast, simple, and reliable method for determination of hexavalent chromium species in soil aqueous and alkaline extracts has been developed. The procedure is based on the ion-pair extraction of Cr(VI) with methyltrioctylammonium chloride (Aliquat 336) into xylene. The extract is analyzed by flame (FAAS) or electrothermal atomic absorption spectrometry (ETAAS). The method allows the detection ...
متن کاملPossible adverse effect of chromium in occupational exposure of tannery workers.
Our aim was to investigate the adverse effects of occupational exposure to trivalent chromium. We measured chromium and iron levels in serum and urine and hemoglobin levels in tannery workers and unexposed persons. We studied three groups of subjects. Group 1 included 15 non-smoking male tannery workers highly exposed to chromium from tanning and retanning departments. Group 2 included 14 non-s...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کامل