A biomechanical analysis of loads on x-ray technologists: a field study.

نویسندگان

  • Shrawan Kumar
  • Lil Moro
  • Yogesh Narayan
چکیده

The aim of the study was to determine the biomechanical loads on radiographers in their occupation. Seven x-ray technologists (one male and six females with combined mean age 32.5 years, mean height 164.6 cm and mean weight 68.3 kg) volunteered to be videotaped while doing their jobs (same as normal and others in a simulated manner). X-ray technologists perform all these tasks regularly every day as part of their assignments. The magnitude of the load handled was measured on weighing scale and recorded. The videotape was played back in the laboratory and the initial and final frames of the tasks investigated were frozen for analysis. The joint angles, the height and weight of the technologist, and the load on their hands (weighed before the task was performed) were input into the 3-D Michigan static strength model for calculation of the lumbosacral load and loads on the joints of the extremities. The lumbosacral compression and shear loads were calculated for 16 tasks commonly performed by all x-ray technologists. The x-ray technologists' work was found to be biomechanically quite demanding. Tasks such as repositioning patients horizontally and lifting a patient from a wheelchair caused lumbosacral compression loads of 7,936N and 8,335N respectively, in which exceeded the maximum permissible limit set by NIOSH in 1981. The action limit defined by NIOSH was exceeded by other tasks. It is also of interest that the majority of the x-ray technologists were female.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Dynamic Analysis of the Biomechanical Model of Head Load Impact Using Differential Transform Method

The dynamic analysis of the biomechanical model of the head load impact using the Differential Transform Method is presented in this paper. In many parts of the world, the problem of traumatic brain injuries (TBI) has led to neurodegenerative dementing disorders and diseases as a result of head load impact from sporting activities, accidents involving the head, etc. have serious effects on huma...

متن کامل

EVALUATION OFDISLOCATION STRUCTURE AND CRYSTALLITE SIZE IN WORN AL-SI ALLOY BY X-RAY DIFFRACTION

Abstract: powerful method for the characterization of microstructures of crystalline materials in terms of crystallite size anddislocation structures. In this paper the effect of the sliding on the microstructure of A356 in the as-cast and heattreated conditions are studied, The X-ray phase analysis shows that with increasing applied load, the dislocationdensity is increased, whereas the crysta...

متن کامل

X-ray peak broadening analysis in LaMnO3+δ nano-particles with rhombohedral crystal structure

In this work, structural and magnetic properties of LaMnO3+δ compound prepared by citrate precursor method and annealed in presence of oxygen are investigated. The structural characterization of LaMnO3+δ by X-ray powder diffraction and using X’pert package and Fullprof program is evidence for a rhombohedral structure (R-3c space group) confirmed by FTIR measurement. The magnetic measurements sh...

متن کامل

CYTOGENETIC BIOMONITORING OF 65 RADIOLOGY TECHNOLOGISTS OCCUPATIONALLY EXPOSED TO CHRONIC DOSES OF X-IRRADIATION IN IRAN

The frequency of chromosomal aberrations was studied in the peripheral blood lymphocytes of 65 radiology technologists CRT) working at hospitals chronically exposed to x-rays. Although film dosimetry did not show the maximal annual permitted dose in any of the examined subjects, cytogenetic analysis detected fairly high levels of chromosomal aberrations in R T compared to unexposed controls...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ergonomics

دوره 46 5  شماره 

صفحات  -

تاریخ انتشار 2003