Static and Dynamic Bearing Tests on a Strip Footing in Saturated

نویسنده

  • Charles R. White
چکیده

This report describes the static and dynamic loading of a 12-inch-wide by 18-inch-deep by 6-foot-long rigid footing, representing the strip footing of a subsurface shelter. Boundary conditions simulated those of a torsionally restrained footing of a flexible arch structure with simulated overburden of 20 feet at one side of the footing. Saturated and partially saturated sand was the test soil. Several soil void ratios were employed, and the effect on the relationship between load and displacement of the footing caused by soil saturation at void ratios higher than the critical void ratio was demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Bearing Capacity of Strip Footings on Pile-Stabilized Slopes

This paper develops an analytical method to calculate seismic bearing capacity of a strip footing, which is located on a slope reinforced with rows of pile. The resistance of passive pile is determined based on normal and shear stress of the soil around the pile, which is then compared to other analytical methods. This comparison indicates an acceptable agreement. The variants of the study incl...

متن کامل

Bearing Capacity of Triangular Shell Foundations Adjacent to the Reinforced Sandy Slopes

This paper investigates response of triangular shell strip footings situated on the sandy slope. A series of reduced-scale plate load tests were conducted to cover different parameters including three shell footing types with different apex angles in addition to a flat footing, four different distances for strip footings from the crest of the slope namely “edge distance” and reinforcement statu...

متن کامل

Numerical and physical modeling of soft soil slope stabilized with stone columns

There can be many reasons for engineers to place the footings near a slope such as leakage of suitable sites or architectural considerations. One of the approaches to increase the amount of bearing capacity, especially in soft soils, is adding stone columns to the soil. In this research, the behavior of a strip footing placed near a stone column reinforced clayey slope was investigated. For thi...

متن کامل

Behavior of Model Circular Footings on Silty Soils with Cellular Supports

An experimental study of the effect of silt and influence of cell confinement on the bearing capacity of circular footings on silty sand was carried out. Laboratory experiments on clean sand and sand containing silt up to 25 % were performed. Cells with different heights and diameters were used to confine the silty sand. The effect of proportion of silt in sand, cell diameter, cell height and t...

متن کامل

Effect of Fuzzy Boundaries on the Bearing Capacity of Footings on Two-Layered Clay

In this study, fuzzy logic was implemented to formulate the fuzziness of layer boundaries for a two-layered clay soil. A field of two-layered clay with fuzzy boundaries between layers was generated, and then the bearing capacity of strip footing on this field was calculated by the assumption of plane-strain conditions. The Mohr-Coulomb failure criterion was used and bearing capacity calculation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016