Evaluation of penetration depth of 2% chlorhexidine digluconate into root dentinal tubules using confocal laser scanning microscope

نویسندگان

  • Sekar Vadhana
  • Jothi Latha
  • Natanasabapathy Velmurugan
چکیده

OBJECTIVES This study evaluated the penetration depth of 2% chlorhexidine digluconate (CHX) into root dentinal tubules and the influence of passive ultrasonic irrigation (PUI) using a confocal laser scanning microscope (CLSM). MATERIALS AND METHODS Twenty freshly extracted anterior teeth were decoronated and instrumented using Mtwo rotary files up to size 40, 4% taper. The samples were randomly divided into two groups (n = 10), that is, conventional syringe irrigation (CSI) and PUI. CHX was mixed with Rhodamine B dye and was used as the final irrigant. The teeth were sectioned at coronal, middle and apical levels and viewed under CLSM to record the penetration depth of CHX. The data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests. RESULTS The mean penetration depths of 2% CHX in coronal, middle and apical thirds were 138 µm, 80 µm and 44 µm in CSI group, respectively, whereas the mean penetration depths were 209 µm, 138 µm and 72 µm respectively in PUI group. Statistically significant difference was present between CSI group and PUI group at all three levels (p < 0.01 for coronal third and p < 0.001 for middle and apical thirds). On intragroup analysis, both groups showed statistically significant difference among three levels (p < 0.001). CONCLUSIONS Penetration depth of 2% CHX into root dentinal tubules is deeper in coronal third when compared to middle and apical third. PUI aided in deeper penetration of 2% CHX into dentinal tubules when compared to conventional syringe irrigation at all three levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Penetration Depth of Conventional and Nano-Particle Calcium Hydroxide into Dentinal Tubules

INTRODUCTION The aim of this in vitro study was to evaluate and compare the penetration depth of conventional (CH) and nano-particle calcium hydroxide (NCH) into dentinal tubules. METHODS AND MATERIALS Ninety human single-rooted teeth were instrumented by RaCe rotary system and after chemomechanical preparation were randomly divided in two equal groups (n=45). In the first group conventional ...

متن کامل

In vitro study of dentinal tubule penetration and filling quality of bioceramic sealer

This study aimed to evaluate the dentinal tubule penetration and filling quality of a bioceramic sealer (iRoot SP). Forty-two roots of extracted adult lower incisors were selected. After instrumentation with Protaper Universal to F3, 40 roots were chosen and randomly divided into 4 groups, as follows: iRoot SP single cone group, iRoot SP warm vertical group, AH Plus single cone group, and AH Pl...

متن کامل

Effect of different final irrigation solutions on dentinal tubule penetration depth and percentage of root canal sealer.

INTRODUCTION The purpose of this study was to evaluate the effects of different solutions used for final irrigation on sealer penetration into dentinal tubules. METHODS Thirty-two recently extracted human mandibular premolar teeth were treated with sodium hypochlorite (NaOCl) irrigation. The samples were divided into 4 groups according to the final irrigation solution used: (1) the EDTA group...

متن کامل

Evaluation of the interaction between sodium hypochlorite and chlorhexidine gluconate and its effect on root dentin.

The combination of sodium hypochlorite (NaOCl) and chlorhexidine (CHX) forms a precipitate. The aim of this study was to evaluate the effect of irrigating root canals with a combination of NaOCl and CHX on root dentin and dentinal tubules by using the environmental scanning electron microscope (ESEM) and a computer program (Photoshop CS2). Forty-four extracted single-rooted human teeth were ins...

متن کامل

In vitro evaluation of dentinal tubule penetration and biomineralization ability of a new root-end filling material.

INTRODUCTION Capasio is being developed as a new generation of endodontic material with potential use as a root-end filling material. The aim of this study was to compare the ability of Capasio and mineral trioxide aggregate (MTA) to penetrate human dentinal tubules and examine the interaction of Capasio and MTA with a synthetic tissue fluid (STF) and root canal walls in extracted human teeth. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2015