False-negative synovial alpha-defensin

نویسندگان

  • Jake R. Adams
  • Adam J. Schwartz
چکیده

We present a case of chronic periprosthetic hip infection diagnosed using the Musculoskeletal Infection Society criteria as the gold standard. The alpha-defensin test was falsely negative. The diagnostic workup of the patient is detailed, along with a discussion regarding the potential reasons behind the misleading alpha-defensin results. To our knowledge, this is the first reported case of a false-negative alpha-defensin test in the setting of an open sinus tract communicating with a culture-positive total hip implant. The alpha-defensin test should be interpreted cautiously, along with all relevant pertinent clinical data. In certain cases, similar to those described here, the Musculoskeletal Infection Society criteria may perform better than this particular biomarker.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Reliable Is the Alpha-defensin Immunoassay Test for Diagnosing Periprosthetic Joint Infection? A Prospective Study

BACKGROUND A key issue in the treatment of periprosthetic joint infection (PJI) is the correct diagnosis. The main problem is lack of diagnostic tools able to diagnose a PJI with high accuracy. Alpha-defensin has been proposed as a possible solution, but in the current literature, there is a lack of independent validation. QUESTIONS/PURPOSES We performed a prospective study to determine (1) w...

متن کامل

The Alpha-defensin Test for Periprosthetic Joint Infection Responds to a Wide Spectrum of Organisms

BACKGROUND The alpha-defensin test has been previously demonstrated to be highly accurate in the diagnosis of prosthetic joint infection (PJI), nearly matching the Musculoskeletal Infection Society definition for PJI. However, the relationship between alpha-defensin levels and differing infecting organism has not yet been investigated. QUESTIONS/PURPOSES The purpose of this study is to descri...

متن کامل

The Alpha-defensin Test for Periprosthetic Joint Infection Outperforms the Leukocyte Esterase Test Strip

BACKGROUND Synovial fluid biomarkers have demonstrated diagnostic accuracy surpassing the currently used diagnostic tests for periprosthetic joint infection (PJI). QUESTIONS/PURPOSES The purpose of this study is to directly compare the sensitivity and specificity of the synovial fluid α-defensin immunoassay to the leukocyte esterase (LE) colorimetric test strip. METHODS Synovial fluid was c...

متن کامل

Comparison of the Effect of Alpha Lipoic Acid (ALA) and Beta-Defensin 1 Protein on Human Sperm Motility and Viability in Different Times of Incubation

Background and Objectives: Antioxidant alpha lipoic acid and β-defensin 1 protein may have a positive effect on the quality of sperm parameters. In this study, the effect of sperm incubation with alpha lipoic acid antioxidant and β-defensin 1 protein were assessed on sperm motility and viability at different times.   Methods: In this experimental study, routine semen analysis was carried out o...

متن کامل

Advancements in Diagnosing Periprosthetic Joint Infections after Total Hip and Knee Arthroplasty

Periprosthetic joint infection (PJI) is a complication of total joint arthroplasty that is challenging to diagnose. Currently, there is no "gold standard" for definite diagnosis of PJI. A multi-criteria definition has been described for PJI based on microbiology cultures, serum markers, such as erythrocyte sedimentation rate and C-reactive protein (CRP), synovial fluid biomarkers, such as leuko...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017