High-speed multifocal array scanning using refractive window tilting.

نویسندگان

  • Anthony Tsikouras
  • Richard Berman
  • David W Andrews
  • Qiyin Fang
چکیده

Confocal microscopy has several advantages over wide-field microscopy, such as out-of-focus light suppression, 3D sectioning, and compatibility with specialized detectors. While wide-field microscopy is a faster approach, multiplexed confocal schemes can be used to make confocal microscopy more suitable for high-throughput applications, such as high-content screening (HCS) commonly used in drug discovery. An increasingly powerful modality in HCS is fluorescence lifetime imaging microscopy (FLIM), which can be used to measure protein-protein interactions through Förster resonant energy transfer (FRET). FLIM-FRET for HCS combines the requirements of high throughput, high resolution and specialized time-resolving detectors, making it difficult to implement using wide-field and spinning disk confocal approaches. We developed a novel foci array scan method that can achieve uniform multiplex confocal acquisition using stationary lenslet arrays for high resolution and high throughput FLIM. Unlike traditional mirror galvanometers, which work in Fourier space between scan lenses, this scan method uses optical flats to steer a 2-dimension foci array through refraction. After integrating this scanning scheme in a multiplexing confocal FLIM system, we demonstrate it offers clear benefits over traditional mirror galvanometer scanners in scan linearity, uniformity, cost and complexity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multifocal optical-resolution photoacoustic microscopy in vivo.

Although ultrasound arrays have been exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved previously to our knowledge. Here we present our development of multifocal OR-PAM using a microlens array for optical illumination and an ultrasound array for photoacoustic detection. Our system is c...

متن کامل

Comparison of higher order aberrations and contrast sensitivity after LASIK, Verisyse phakic IOL, and Array multifocal IOL.

PURPOSE To evaluate higher order aberrations and contrast sensitivity after LASIK, implantation of the Verisyse phakic intraocular lens (IOL), and refractive lens exchange with the Array multifocal IOL. METHODS In a prospective, non-randomized case series, LASIK was performed in 20 eyes with the Technolas 217z excimer laser (Bausch & Lomb, Rochester, NY), a Verisyse phakic IOL (AMO Inc, Santa...

متن کامل

Refractive lens exchange with an array multifocal intraocular lens.

PURPOSE To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15....

متن کامل

Visual Results Following Implantation of a Refractive Multifocal Intraocular Lens in One Eye and a Diffractive in the Contralateral Eye

Objectives To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a "mix and match" approach. Materials and Methods Twenty patients (40 eyes) were involved in this prospective, nonrandomized study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients' dominant eyes and diffractive multifocal IOLs (Tecni...

متن کامل

Wide-field two-dimensional multifocal optical-resolution photoacoustic-computed microscopy.

Optical-resolution photoacoustic microscopy (OR-PAM) is an emerging technique that directly images optical absorption in tissue at high spatial resolution. To date, the majority of OR-PAM systems are based on single-focused optical excitation and ultrasonic detection, limiting the wide-field imaging speed. While 1D multifocal OR-PAM (1D-MFOR-PAM) has been developed, the potential of microlens a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical optics express

دوره 6 10  شماره 

صفحات  -

تاریخ انتشار 2015