Comparison of Corneal Power and Astigmatism between Simulated Keratometry, True Net Power, and Total Corneal Refractive Power before and after SMILE Surgery
نویسندگان
چکیده
Purpose. To compare the mean corneal power (Km) and total astigmatism (Ka) estimated by three methods: simulated keratometry (simK), true net power (TNP), and total corneal refractive power (TCRP) before and after femtosecond laser small incision lenticule extraction (SMILE) surgery. Methods. A retrospective, cross-sectional study. SimK, TNP, and TCRP from a Scheimpflug analyzer were obtained from 144 patients before and 6 months after SMILE surgery. Km and Ka were recorded as the mean of individual paracentral rings of 1.0 to 8.0 mm (R1 to R8). The surgically induced changes in Km (delta-simK, delta-TNP, and delta-TCRP) and Ka (delta-simKa, delta-TNPa, and delta-TCRPa) were compared to the changes in spherical equivalent of the cycloplegic refraction (delta-SE) and astigmatism (delta-RA). Results. Preoperatively, astigmatism values were greatest with simKa from R1 to R5 and greatest with TCRPa from R6 to R8. Astigmatism values were smallest with TNPa from R1 to R7. Postoperatively, astigmatism values were greatest with simKa from R1 to R5 and greatest with TCRPa from R6 to R8. Delta-TCRP3 and Delta-TCRP4 matched delta-SE most closely, and delta-TCRPa3 matched delta-RA most closely. Conclusions. TCRP proved to be the most accurate method in estimating corneal power and astigmatism both before and after SMILE surgery.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملRefractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power
PURPOSE To determine whether the total corneal refractive power (TCRP) value, which is based on measurement of both anterior and posterior corneal astigmatism, is effective for toric intraocular lens (IOL) calculation with AcrySof(®) Toric IOLs. PATIENTS AND METHODS A consecutive series of cataract surgery cases with AcrySof toric IOL implantation was studied retrospectively. The IOLMaster(®)...
متن کاملThe Comparison of Central and Mean True-Net Power (Pentacam) in Calculating IOL-Power After Refractive Surgery
PURPOSE To compare the accuracy of central true net corneal power (cTNP) and mean true net corneal power (mTNP) of the Pentacam system to give a keratometry (K) reading for calculating IOL (intraocular lens) power in eyes following refractive surgery. METHODS Refraction, an automated K-reading (Km), cTNP and mTNP were measured for 15 eyes that required cataract surgery and had previously unde...
متن کاملComparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators
PURPOSE To compare the astigmatic power of toric intraocular lenses (IOLs) obtained from the AcrySof, TECNIS, and iTrace toric calculator in patients with preoperative with-the-rule (WTR) or against-the-rule (ATR) corneal astigmatism. MATERIALS AND METHODS Fifty eyes with cataract and corneal astigmatism greater than 0.75 diopters were enrolled in each group (WTR and ATR). Keratometric values...
متن کاملهمبستگی آستیگماتیسم رفرکتیو، قرنیهای و لنتیکولار در افراد داوطلب جراحی رفرکتیو
Background and purpose: Astigmatism is a common optical dysfunction, effective on various visual outcomes and one of the important criteria of refractive surgery. The aim of present study was to evaluate the correlation between refractive, corneal and residual astigmatism in refractive surgery candidates. Materials and methods: In this cross-sectional descriptive, analytical study, 200 patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017