Monitoring bacterial contamination in equine platelet concentrates obtained by the tube method in a clean laboratory environment under three different technical conditions.

نویسندگان

  • M E Alvarez
  • C E Giraldo
  • J U Carmona
چکیده

REASONS FOR PERFORMING STUDY There is a growing interest in the use of autologous platelet concentrates (PCs) as treatment for chronic musculoskeletal diseases in horses. However, there is no information on the risk of bacterial contamination during their preparation. OBJECTIVES To: 1) assess the risk of bacterial contamination in equine PCs obtained by the tube method under 3 technical conditions: a) in a laminar flow cabinet, in a clean laboratory environment both with (b) and without (c) Bunsen burner; 2) identify the critical points of the process of PCs preparation with risk of bacterial contamination; and 3) identify the potential bacterial contaminants in the process and their antibiotic susceptibility. METHODS Bacteriological samples were taken from: the skin (shaved or unshaved) of the venipuncture site in 15 horses, both before and after being disinfected; hands and throat of the operator; caps of the tubes where the blood was processed; environment where the equine blood samples were collected; laboratory environment; laminar flow cabinet; bacteriological stove; and PCs obtained under 3 technical conditions. RESULTS Bacteria were isolated from nonaseptically prepared equine skin, hands and throat of the operator, and the place where the blood samples were taken. Bacteria were not isolated from tube caps, laboratory environment, laminar flow cabinet or PCs. The isolated bacteria were normal biota from equine skin, human skin and throat, and environmental contaminants. Of the isolated bacteria, 23% were resistant to penicillin, 19% to ampicillin, 2.12% to ceftiofur, 3.2% to sulphamethoxazole/trimethoprim and 1.1% to enrofloxacin. Resistance to amikacin and gentamicin was not seen. CONCLUSIONS AND POTENTIAL RELEVANCE Uncontaminated PCs can be obtained by the tube method in a clean laboratory environment without the need for either a laminar flow cabinet or a Bunsen burner. It is mandatory to perform the procedure following strict aseptic technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Procedures for Platelet Products Contaminated with Strains of Staphylococcus Epidermidis and Klebsiella

Abstract Background and Objective: Given that microbial contamination is the third largest cause of mortality caused blood transfusion, the examination of contamination in platelet concentrates is essential in blood transfusion centers. The purpose of this study was to achieve a rapid test for bacterial contamination of platelets concentration. Material and Methods: This laboratory ...

متن کامل

An Overview on Platelet-derived Microparticles in Platelet Concentrates: blood collection, method preparation and storage

Preparations of platelet concentrates (PCs) that are stored under blood bank conditions and used for transfusion purposes, appear to be enriched in platelet derived-microparticles (PMPs) with high coagulant activity that may change platelet efficacy and safety issues. High shear stress could cause shedding of PMPs from the platelet plasma membrane, platelet aggregation, and activation of the co...

متن کامل

Platelet Septic Transfusion Reactions in Patients With Hemato-Oncological Diseases

Background & Objective: Bacterial, contamination of blood components are a significant risk for transfusion reactions. Inherently, platelet concentrates (PCs) are vulnerable to bacterial contamination, due to the storage condition of processed PCs at room temperature, which provide very suitable conditions for the proliferation of microorganisms....

متن کامل

Comparative Study of Four Platelet-Rich Plasma Methods for Preparing Platelet Concentrates

Background: Platelet preparations have been used for a wide variety of clinical applications such as hemorrhage, tissue engineering and cellular therapy. Platelet concentrates can be prepared by the apheresis method or from the whole blood using the Buffy-coat or Platelet-rich plasma methods. The purpose of this study was to compare four variations of platelet-rich plasma method based on double...

متن کامل

Bacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran

There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Equine veterinary journal

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 2010