Cerate-arsenite measurement of iodine in the subnanogram range.

نویسندگان

  • H Hoch
  • C G Lewallen
چکیده

A method for the measurement of subnanogram quantities of iodine is describeo. Procedural detail and precision of results are presented for application of the method to protein-bound or total iodine in duplicate on 12.3 ii.l serum. Following wet ashing with chloric reagent, the iodine-catalyzed cerate-arsenite reaction was carried out at temperatures between 23 and 27#{176}, and the reaction rate coefficients were corrected to refer to 25.0#{176} by an empirical equation. The recovery of iodine standards, added to the precipitated protein before ashing, ranged between 96 and 106%. One contributing cause of this variation is the formation of an inhibitor of unknown nature during heating. Samples were brought to a final volume of 180 .l prior to fading. The detection limit was of the order of 0.04 ng iodine. For 62 serum samples having a mean iodine content of 0.558 ng (range 0.15-1.31 ng), the standard deviation calculated from duplicates was 0.019 ng/180 d. For 31 samples having a mean iodine content of 2.24 ng (range 1.61-2.96 ng), the standard deviation was 0.039 ng/180 l. Expressed as micrograms of iodine per 100 ml of serum, the mean ± standard deviation for the group of 62 samples was 4.54 ± 0.15.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Iodine in Consumed Salts at the Distribution Level and Assessing Post-Training Attitude Status in Providers in Qom

Background and Objective: In order to properly grow the body, the production of thyroxin hormones and Etc. are highly dependent on iodine level. This study was conducted to measure the iodine level in edible salts consumed by food supply centers and training operators to evaluate their performance. Materials and Methods: This semi-experimental study was carried out in Qom city during the perio...

متن کامل

توزیع ید در ادرار و شیر مادران در دوران پس از زایمان در گرگان ، سال 1382

 Background : are reliant on adequate maternal iodine intake. The aim of this study was to evaluate iodine sufficiency in lactating women in Iran .  Materials and methods referred to the Taleghani Hospital of Gorgan between April and June 2003. Subjects were within the 1 st -6 th month of their postpartum period. Goiter was graded according to WHO classification. Spot urine ( 2-3 ml) and breast...

متن کامل

Evaluation of Iodine in Distributed Salts in Abarkouh City in 2017-2018

Introduction: Iodine deficiency and associated disorders, which lead to a wide range of clinical manifestations, have been raised as one of the health and nutritional problems in Iran. Therefore, this study was aimed to investigate the amount of iodine in distributed salts in Abarkouh city in 2017-2018. Materials and Methods: Random sampling was done by census on all 30 distributed brands in A...

متن کامل

Stereological Study of the Protective Role of Curcumin on Histological Changes of Seminal Vesicle in Mice Following Treatment with Sodium Arsenite

Background & Aims: Sodium arsenite causes oxidative stress and endocrine disorders in the reproductive system. The aim was to investigate the protective role of curcumin as an antioxidant on the seminal vesicle tissue in adult mice treated with sodium arsenite. Materials & Methods: Adult male Naval Medical Research Institute (NMRI) mice were randomly divided into 5 groups (six mice per group) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 1969