Although reproducible results can be obtained in photometric set-point titrations of submicromolar amounts (5 -lo+ M and higher) of calcium(I1) and zinc(I1) by using an ? automatic titrator, the systematic error can be considerable. This error is partly intrinsic ; in nature, but there is an additional error caused by dilution in successive titrations_ Accurate values can be obtained only when standardization and actual titrations are performed under the same conditions of dilution, set-point, indicator concentrations, etc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison Of Calcium, Phosphorus, Iron And Zinc In Some Food Items With The Amounts Presented By Nutritionist Iv Software

Introduction: Considering that the dietary intake analyses conducts using software that designed in foreign countries, based on foreign food composition tables, the present study aimed to compare the amounts of calcium, Iron, phosphorus and zinc in some native food items with Nutritionist IV software values. Methods: 15 food items from 22 areas of Tehran city were analyzed chemically and compar...

متن کامل

Effect of Aerobic Training on Estrogen, PTH, Calcium, Alkaline Phosphatase and Albumin, in Postmenopausal Women

Objectives: The purpose of this study was to consider the effect of eight weeks aerobic training on PTH, albumin, calcium, alkaline phosphatesand estrogen levels in postmenopausal women. Methods & Materials: 22 postmenopause women, 55-70 years, of Jahandidegan center in Tehran were selected and randomly divided into two groups: [experimental (12) and control (10)]. They had aerobic training ...

متن کامل

مقایسه‌ی دریافت ریزمغذی‌ها در مبتلایان به مولتیپل اسکلروز با نیازهای تغذیه‌ای در شهر تهران

Background & Objectives: Multiple Sclerosis (MS) is the most prevalent autoimmune disease of the nervous system in young adults. There are currently more than 30000 cases in Iran and the number is increasing everyday.The objective of this study was to measure the amount of vitamin and mineral intake in MS patients and to compare it with reference values. Methods: We randomly selected 108 re...

متن کامل

Artificial Neural Network Modeling for Predicting of some Ion Concentrations in the Karaj River

The water quality of the Karaj River was studied through collecting 2137 experimental data set gained by 20 sampling stations. The data included different parameters such as T (temperature), pH, NTU (turbidity), hardness, TDS (total dissolved solids), EC (electrical conductivity) and basic anion, cation concentrations. In this study a multi-layer perceptron artificial neural network model was d...

متن کامل

Competition of zinc, cadmium and calcium for binding sites in sperm of trout and carp

Heavy metal pollutions of aquatic ecosystems have already raised many concerns on aquaticorganisms’health and survival especially on their sperm. The effects of a single metal on sperm may be totallydifferent from cocktail of several metals because of their interactions, so the effects of zinc, cadmium andcalcium on the trout and carp sperms and their competition have been examined by incubatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000