The Effect of Corneal Irregularity on Astigmatism Measurement by Automated versus Ray Tracing Keratometry

نویسندگان

  • Hyun Cheol Roh
  • Roy S. Chuck
  • Jimmy K. Lee
  • Choul Yong Park
  • Vishal Jhanji.
چکیده

The aim of this study was to compare the effect of corneal irregularity on astigmatism assessment using automated keratometry (AK) (IOLMaster) versus ray tracing keratometry (Pentacam). This is an observational case series approved by the institutional review board of Dongguk University Hospital, Goyang, South Korea. A total of 207 eyes of 207 cataract patients were included. Preoperative corneal astigmatism was measured by both IOLMaster and Pentacam. Corneal irregularity index (IR) was calculated in Fourier analysis map of Pentacam. AK by IOLMaster and total corneal refractive power (TCRP, 3 mm and 4 mm zone analysis with pupil centered) by Pentacam were selected and the difference between the 2 measurements (delta Δ) was calculated using vector analysis. Ocular residual astigmatism (ORA) after cataract surgery was calculated by subtracting 6-month postoperative refractive astigmatism (RA) measurements from corresponding preoperative values (AK, TCRP3, and TCRP4). The mean irregularity index measured was 0.042 ± 0.019 mm (mean ± standard deviation) and was positively correlated with age and magnitude of corneal astigmatism (P < 0.001 and P < 0.05). The difference (Δ) between TCRPs and AK (ΔTCRPs-AK) was 0.43 ± 0.37 (TCRP3) and 0.39 ± 0.35 (TCRP4) diopters. Linear regression analysis revealed that age (P < 0.001), IR (P < 0.001), and AK (P < 0.001) were positively correlated with ΔTCRPs-AK. In highly irregular corneas (IR over 0.77 diopters: mean + 2 standard deviation), postoperative ORAs calculated using TCRPs were significantly lower than ORAs calculated using AK. Corneal irregularities significantly impact astigmatism assessment by IOLMaster (AK) and Pentacam (TCRPs). Compared with AK, TCRPs were more accurate in predicting postoperative residual astigmatism in highly irregular corneas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Anterior surface-based keratometry compared with Scheimpflug tomography-based total corneal astigmatism.

PURPOSE Description of total corneal refractive power (TCRP) astigmatism by ray tracing using a Scheimpflug tomographer. METHODS Analysis of Scheimpflug tomography measurements to determine 3-mm-zone TCRP astigmatism (CATCRP) by ray tracing calculations, astigmatism in 15°-zone from simulated keratometry (CASim-K), anterior-surface astigmatism (CAant), and posterior-surface astigmatism (CApos...

متن کامل

Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators

PURPOSE To compare the astigmatic power of toric intraocular lenses (IOLs) obtained from the AcrySof, TECNIS, and iTrace toric calculator in patients with preoperative with-the-rule (WTR) or against-the-rule (ATR) corneal astigmatism. MATERIALS AND METHODS Fifty eyes with cataract and corneal astigmatism greater than 0.75 diopters were enrolled in each group (WTR and ATR). Keratometric values...

متن کامل

Color light-emitting diode reflection topography: validation of keratometric repeatability in a large sample of wide cylindrical-range corneas

PURPOSE To investigate repeatability of steep and flat keratometry measurements, as well as astigmatism axis in cohorts with normal range and regular astigmatic such as: eyes following laser-assisted in situ keratomileusis (LASIK) and normal population, as well as cohorts of high and irregular astigmatism such as keratoconic eyes, and keratoconic eyes following corneal collagen cross-linking, e...

متن کامل

Refractive versus corneal changes after photorefracive keratectomy for astigmatism.

PURPOSE To define measures of assessing success and subsequent ways to improve excimer laser treatment of astigmatism. METHODS We studied 97 eyes of 79 patients, followed for 12 months, that underwent photorefractive keratectomy (PRK) for myopia and astigmatism with a VISX 20/20 excimer laser. Preoperative spherical equivalent refraction at the corneal plane was between -1.00 and -15.00 D. Me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015