Study the Energy Minimization Techniques in Order to Improve the Quality of an Mir Image
نویسندگان
چکیده
This Paper proposed the characterization of atherosclerosis lesions in vivo using Magnetic Resonance Imaging (MRI). For this, it uses an energy minimization approach to equalize the contrast of MR image. To enable the use of voxel gray values for interpretation of disease, we created a new method, energy minimization with a spline model, to correct the severe (80%) intensity in homogeneity that arises from the surface coil array. Intensity in intravascular micro coils induces shading artifacts across the data. Artifacts are modelled as a smooth multiplicative bias field with a cubic spline. The cubic spline is optimized to minimize the entropy of the correct image The entropy based method does not require classification and robustly addresses some problems that are more severe than those found in brain imaging, including noise, steep bias field, sensitivity of artery wall voxels to edge articrafts, and signal voids near the artery wall. All simulations are done in MATLAB.
منابع مشابه
Optimization of Bremsstrahlung imaging in Yttrium internal radiation therapy
Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...
متن کاملAn Adaptive Hierarchical Method Based on Wavelet and Adaptive Filtering for MRI Denoising
MRI is one of the most powerful techniques to study the internal structure of the body. MRI image quality is affected by various noises. Noises in MRI are usually thermal and mainly due to the motion of charged particles in the coil. Noise in MRI images also cause a limitation in the study of visual images as well as computer analysis of the images. In this paper, first, it is proved that proba...
متن کاملImage Quality and Entrance Surface Dose Evaluation of Lateral Cervical Spine: A Study Using Grid and Non-Grid Techniques
Introduction: The purpose of this study is to investigate the effects of grid and non-grid techniques in the lateral cervical spine radiography on image quality and entrance surface dose (ESD). Although image quality and radiation doses have been studied by researchers, there is still a dearth of information on image quality and patient dose with different techniques. Material and Methods: The...
متن کاملروشی جدید برای تطبیق تصاویر پزشکی همنوع برپایه مدلهای دگردیسپذیر و کاربرد آن برای تصاویر CT قفسه سینه
In 4D CT images of the thorax, deformation is caused by both the tissue movement and breathing. Tissue movement can be estimated at various time intervals by image registrstion. In this paper, a new deformable model is proposedfor non-regid medical image resgistration. The energy funational of the suggested algorithm consists of two internal (regulator) and external terms. By minimization of th...
متن کاملMulti-Focus Image Fusion in DCT Domain using Variance and Energy of Laplacian and Correlation Coefficient for Visual Sensor Networks
The purpose of multi-focus image fusion is gathering the essential information and the focused parts from the input multi-focus images into a single image. These multi-focus images are captured with different depths of focus of cameras. A lot of multi-focus image fusion techniques have been introduced using considering the focus measurement in the spatial domain. However, the multi-focus image ...
متن کامل