Complications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures
نویسندگان
چکیده
Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]. The plate design is anatomic and low profile, minimizing soft-tissue problems, and plating on the volar side of the radius makes it relatively easy to reduce the fracture while preventing extensor tendon irritation [5] In the last years, there has been a shift in operative technique from pin fixation or external fixation to volar locking plates, because the clinical and radiological outcomes have been good. [6]. However, several authors have reported serious complications when using volar locking plate fixation in unstable distal radius fractures and although the results and severity of complications varies [7], the matter of complications will have to be addressed when implementing new methods. As with all new methods, the rate of complications seem to decrease with increasing surgeon experience [8].
منابع مشابه
Complications of volar plating of distal radius fractures.
Open reduction and internal fixation has been shown to be effective in the treatment of unstable distal radius fractures. When a dorsal approach is used, extensor tendons rupture or irritation are frequent and well known complications. Complications associated with volar plate fixation have not been studied to the same extent. In this study a homogenous series of 90 patients treated by volar pl...
متن کاملWrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year
BACKGROUND AND PURPOSE Promising results have been reported after volar locked plating of unstable dorsally displaced distal radius fractures. We investigated whether volar locked plating results in better patient-perceived, objective functional and radiographic outcomes compared to the less invasive external fixation. PATIENTS AND METHODS 63 patients under 70 years of age, with an unstable e...
متن کاملExtensor indicis proprius and extensor digitorum communis rupture after volar locked plating of the distal radius--a case report.
Distal radius fractures are among the most commonly encountered fractures in the extremities. Volar plating of distal radius fracture has gained popularity in recent years with the introduction of the locked plating system. Complications of volar plating include extensor and flexor tendon rupture. Here we present a case report of an extensor indicis proprius and extensor digitorum communis to i...
متن کاملVolar Distal Radius Anatomy Applied to the Treatment of Distal Radius Fracture.
Volar locking plate (VLP) fixation has become the standard surgical treatment for distal radius fractures. However, flexor tendon rupture is one of the major complications following volar plating. This detailed review on the anatomy and morphology of the volar distal radius might facilitate appropriate placement of the volar plate and thereby avoid flexor tendon rupture. We introduce safe and s...
متن کاملStainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial
BACKGROUND Distal radius fractures are among the most common fractures seen in the hospital emergency department. Of these, over 40% are considered unstable and require some form of fixation. In recent years with the advent of low profile plating, open reduction and internal fixation (ORIF) using volar plates has become the surgical treatment of choice in many hospitals. However, it is currentl...
متن کامل