SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator.

نویسندگان

  • L Wang
  • B Nelson
چکیده

PURPOSE A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). METHODS The phantom was first scanned with a CT scanner at 0.625 slice thickness and exported to the Cyberknife Muliplan (v4.6) treatment planning system. An isocentric treatment plan was created consisting of ten beams of 25 Monitor Units each using Iris apertures of 7.5, 10, 15, 20, and 25 mm. The plan was delivered six times in two days on the Cyberknife G4 system with fiducial tracking on the four metal fiducials embedded in phantom with re-positioning between the measurements. The beam vectors (X, Y, Z) are measured and compared with the plan from the machine delivery file (XML file). The Iris apertures (FWHM) were measured from the beam flux map and compared with the commissioning data. RESULTS The average beam positioning accuracies of the six deliveries are 0.71 ± 0.40 mm, 0.72 ± 0.44 mm, 0.74 ± 0.42 mm, 0.70 ± 0.40 mm, 0.79 ± 0.44 mm and 0.69 ± 0.41 mm respectively. Radiation beam width (FWHM) variations are within ±0.05 mm, and they agree with the commissioning data within 0.22 mm. The delivery time for the plan is about 7 minutes and the results are given instantly. CONCLUSION The experimental results agree with stated sub-millimeter delivery accuracy of Cyberknife system. Beam FWHM variations comply with the 0.2 mm accuracy of the Iris collimator at SAD. The XRV-100 system has proven to be a powerful tool in performing end-to-end type tests for Robotic Image Guided Radiosurgery Daily QA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The design, physical properties and clinical utility of an iris collimator for robotic radiosurgery.

Robotic radiosurgery using more than one circular collimator can improve treatment plan quality and reduce total monitor units (MU). The rationale for an iris collimator that allows the field size to be varied during treatment delivery is to enable the benefits of multiple-field-size treatments to be realized with no increase in treatment time due to collimator exchange or multiple traversals o...

متن کامل

Development of a micro-computed tomography-based image-guided conformal radiotherapy system for small animals.

PURPOSE To report on the physical aspects of a system in which radiotherapy functionality was added to a micro-computed tomography (microCT) scanner, to evaluate the accuracy of this instrument, and to and demonstrate the application of this technology for irradiating tumors growing within the lungs of mice. METHODS AND MATERIALS A GE eXplore RS120 microCT scanner was modified by the addition...

متن کامل

SU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.

PURPOSE The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with GammaKnife 4C utilizing the updated physics data in GammaPlan v10.1. METHODS ...

متن کامل

Report of AAPM TG 135: quality assurance for robotic radiosurgery.

The task group (TG) for quality assurance for robotic radiosurgery was formed by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance (QA) Subcommittee. The task group (TG-135) had three main charges: (1) To make recommendations on a code of practice for Robotic Radiosurgery QA; (2) To make recommen...

متن کامل

SU-E-T-398: Verification of Gamma Knife EXtend System Based Fractionated Treatment Planning Using EBT2 Film.

PURPOSE To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for eXtend Frame based treatment planning involved creating a dental impression, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2014