Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification

نویسندگان

  • Ali Şimşek
  • Burak Bilgin
  • Musa Çapkın
  • Şemsettin Bilak
  • Mete Güler
  • Ali Hakim Reyhan
چکیده

PURPOSE To investigate changes in anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil diameter (PD), and intraocular pressure (IOP) after uneventful phacoemulsification cataract surgery with intraocular lens implantation. METHODS A total of 132 eyes of 132 patients (87 men and 45 women) that underwent uneventful phacoemulsification cataract surgery and intraocular lens implantation were prospectively studied. The mean age of the patients was 63.68 ± 12.51 years. All patients were evaluated preoperatively and at 1 month postoperatively with the Sirius 3D Rotating Scheimpflug camera topography system. The ACD, CV, ACA, ACV, CCT, HVID, and PD measurements were recorded. IOP was measured using the Goldmann applanation tonometer, which was corrected for CCT of the Sirius device using Ehlers' formula. RESULTS The preoperative mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 2.79 ± 0.45 mm, 124.73 ± 25.72 mm(3), 42.09 ± 7.49(0), 523.87 ± 41.97 microns, 55.37 ± 4.89 mm(3), 3.98 ± 1.23 mm, 11.72 ± 0.67 mm, and 14.74 ± 2.59 mmHg, respectively. Three months postoperatively, the mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 3.45 ± 0.6 mm, 162.52 ± 23.79 mm(3), 51.46 ± 5.63(0), 526.21 ± 44.45 microns, 56.23 ± 5.12 mm(3), 2.87 ± 0.45 mm, 11.91 ± 0.75 mm, and 12.02 ± 1.83 mmHg, respectively. There was a statistically significant increase in mean postoperative ACD, ACV, ACA, CV, and HVID compared with the corresponding preoperative values (p < 0.05). CCT remained stable after surgery. Postoperative PD and IOP were significantly decreased compared to corresponding preoperative values (p < 0.05). CONCLUSIONS Preoperative measurements by the Sirius 3D Rotating Scheimpflug camera topography system might help surgeons to predict postoperative changes resulting from phacoemulsification and intraocular lens implantation. This is a noncontact, noninvasive, and comfortable system for patients that is highly reliable and repeatable for anterior segment measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy

Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...

متن کامل

Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation

OBJECTIVES To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. MATERIALS AND METHODS Twenty-t...

متن کامل

Development of Toxic Anterior Segment Syndrome Immediately after Uneventful Phaco Surgery

PURPOSE We report on 15 cases of suspected toxic anterior segment syndrome after uneventful phaco surgery. METHODS We retrospectively reviewed the charts of patients who had developed toxic anterior segment syndrome (TASS) after uneventful phacoemulsification for senile cataracts between April and December of 2005. Clinical features and all possible causes were investigated including irrigati...

متن کامل

Nonarteritic anterior ischemic optic neuropathy after uneventful phacoemulsification: case report.

To report a case of nonarteritic anterior ischemic optic neuropathy (NAION) after uneventful cataract extraction and intraocular lens implantation. Prospective, observational case report and literature review. We report the case history of a 74-year-old woman who underwent phacoemulsification and developed sudden loss of vision on the 13th postoperative day. After complete ocular and systemic e...

متن کامل

Evaluation of bacterial contamination rate of the anterior chamber during phacoemulsification surgery using an automated microbial detection system.

AIM To assess the incidence of anterior chamber bacterial contamination during phacoemulsification surgery using an automated microbial detection system (BacT/Alert). METHODS Sixty-nine eyes of 60 patients who had uneventful phacoemulsification surgery, enrolled in this prospective study. No prophylactic topical or systemic antibiotics were used before surgery. After antisepsis with povidone-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2016