Spirometric abnormalities associated with chronic bronchitis, asthma, and airway hyperresponsiveness among boilermaker construction workers.
نویسندگان
چکیده
STUDY OBJECTIVES In a 2-year longitudinal study of boilermaker construction workers, we found a significant association between working at oil-fired, coal-fired, and gas-fired industries during the past year and reduced lung function. In the present study, we investigated whether chronic bronchitis, asthma, or baseline methacholine airway responsiveness can explain the heterogeneity in lung function response to boilermaker work. DESIGN This study is part of an ongoing prospective cohort study of boilermakers. Exposure was assessed with a work history questionnaire. Spirometry was performed annually to assess lung function. A generalized estimating equation approach was used to account for the repeated-measures design. SETTING Boilermaker union members. PARTICIPANTS One hundred eighteen boilermakers participated in the study. INTERVENTIONS None. MEASUREMENTS AND RESULTS Self-reported history of chronic bronchitis and asthma were associated with a larger FEV1 reduction in response to workplace exposure at coal-fired and gas-fired industries. Although we found a high prevalence (39%) of airway hyperresponsiveness (provocative concentration of methacholine causing a 20% fall in FEV1 of < 8 mg/mL) among boilermakers, we did not find a consistent pattern of effect modification by airway responsiveness. CONCLUSIONS Although chronic bronchitis and asthma were associated with a greater loss in lung function in response to hours worked as a boilermaker, and therefore they acted as effect modifiers of the exposure-lung function relationship, airway hyperresponsiveness did not. However, the high prevalence of airway hyperresponsiveness found in the cohort may be a primary consequence of long-term workplace exposure among boilermakers.
منابع مشابه
Interaction of atopy and smoking on respiratory effects of occupational dust exposure: a general population-based study
BACKGROUND For individual exposures, effect modification by atopy or smoking has been reported on the occurrence of occupational airway disease. It is unclear if effect modification can be studied in a general population by an aggregated exposure measure. Assess relationship between airway obstruction and occupational exposure using a job-exposure-matrix (JEM) classifying jobs into 3 broad type...
متن کاملAsthma characteristics in cleaning workers, workers in other risk jobs and office workers.
Several studies have demonstrated an excess risk for asthma among cleaning workers. The aim of this analysis was to compare clinical, immunological and functional characteristics associated with asthma in cleaners and other occupational groups. Cleaners, workers exposed to high molecular weight (MW) agents, workers exposed to low MW agents, and office workers were identified from an internation...
متن کاملPrevalence of and relationship between rhinoconjunctivitis and lower airway diseases in compost workers with current or former exposure to organic dust.
INTRODUCTION AND OBJECTIVE The relationship between allergic rhinitis and allergic asthma is well characterized. However, it remains unknown whether an association exists between symptoms of upper and lower airway diseases and occupational bioaerosol exposure beyond the scope of allergy. MATERIALS AND METHODS The current cross-sectional study focuses on 190 current and 59 former compost worke...
متن کاملDifferences in airway responsiveness to acetaldehyde and methacholine in asthma and chronic bronchitis.
Inhaled acetaldehyde may induce bronchoconstriction in asthmatic subjects and provides a new method to investigate airway responsiveness. The objective of the study was to determine whether acetaldehyde was a more specific stimulus than methacholine in differentiating asthma from chronic bronchitis with or without airflow limitation. Bronchial provocation challenges with methacholine and acetal...
متن کاملDevelopment of irreversible airflow obstruction in a patient with eosinophilic bronchitis without asthma.
Eosinophilic bronchitis is a recently described condition presenting with chronic cough and sputum eosinophilia without the abnormalities of airway function seen in asthma. The patient, a 48-yr-old male who had never smoked, presented with an isolated chronic cough. He had normal spirometric values, peak flow variability and airway responsiveness, but an induced sputum eosinophil count of 33% (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 121 6 شماره
صفحات -
تاریخ انتشار 2002