The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.
نویسندگان
چکیده
Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses.
منابع مشابه
Comparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis
Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...
متن کاملBioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women
Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...
متن کاملComparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis
Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...
متن کاملComparisons of a Multi-Frequency Bioelectrical Impedance Analysis to the Dual-Energy X-Ray Absorptiometry Scan in Healthy Young Adults Depending on their Physical Activity Level
This study aimed at comparing BIA and DXA results in assessing body composition in young adults depending on their physical activity level. Eighty healthy 19-30 years old subjects were enrolled and their body composition (Fat Mass and Fat-Free Mass) was assessed by dual-energy X-ray absorptiometry (DXA) and by a newly developed Bioelectrical Impedance Analyzer (BIA - Tanita MC780). A seven-day ...
متن کاملBody fat measured by bioelectrical impedance in Hong Kong Chinese children.
OBJECTIVE To establish reference standards for percentage body fat measured in Hong Kong Chinese children, by methods involving bioelectrical impedance analysis. DESIGN Cross-sectional study. SETTING Thirty-six randomly selected primary and secondary schools and a teaching hospital in Hong Kong. PARTICIPANTS A total of 14 842 students randomly selected from the schools and two additional ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nutrition research
دوره 30 5 شماره
صفحات -