Estimation of Radon Exhalation Rate and Radium Content in Soil Samples of Pathankot District, Punjab Using LR-115 Plastic Detector

نویسندگان

  • Ajay Kumar
  • Saurabh Narang
چکیده

In the present investigation, soil samples were collected from 10 villages belonging to Pathankot district, Punjab, India and assessed for radium content using LR-115 plastic detector. The ‘track etch’ technique has been employed for measuring the radium content. From the radium content, radon exhalation rates and mass exhalation rates were calculated for these samples. The mass exhalation rate in soil samples has been found to vary from 1.91 mBqkg-1h-1 to 6.55 mBqkg-1h-1 and radium concentration varies from 1.39 Bq/Kg to 5.31 Bq/kg. A strong correlation (correlation coefficient= 0.99) has been observed between radium and radon exhalation rate. The radium content in soil in the study area is below the safe limit recommended by UNSCEAR [1].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of radium concentration and radon exhalation rates of soil samples collected from some areas of Bulandshahr district, Uttar Pradesh, India using plastic track detectors

Background: Radon is an odourless, colourless and tasteless gas and it is the first cause of lung cancer among non- smokers. The assessment of the level of radium in building materials helps in understanding the radiological implications. It has been observed that everyone has some levels of exposure to them. Therefore measurement of radium and radon in the soil samples are important f...

متن کامل

The effective radium content and radon exhalation rate in hair dyes samples

Background: Hair dyes are the important materials widely used by various peoples in Iraq and other countries. The present work investigates the presence of the effective radium content and radon exhalation rate in hair dyes samples. Materials and Methods: Twenty  hair dyes  samples were collected from Iraqi markets. Sealed can technique using LR-115 type II plastic track detector s ha...

متن کامل

Radium and radon exhalation studies of soil

Background: Everyone is exposed to radon because it is present everywhere with varying concentrations. Radon and its progeny are well established as lung carcinogenic. Materials and Methods: Track etch technique using LR-115 plastic track detectors has been used to measure the effective radium content and radon exhalation rates in soil samples collected from urban area of Etah district...

متن کامل

Radon Exhalation Rates and Radium Estimation Studies in Soil Samples Collected from Various Locations in the Environment of Shahjahanpur District of Uttar Pradesh, India

The measurements of radium content and radon exhalation rates in terms of mass and area in soil samples collected from various locations in the shahjahanpur District were carried by using cylindrical can technique(CCT) based on LR-115 type II plastic track detector. From the result it was found that the effective radium content in the study area varies from 0.485Bq/kg to 2.503Bq/kg with an aver...

متن کامل

An Overview on Studying Rn Exhalation Rates using Passive Technique Solid-State Nuclear Track Detectors

Problem statement: Uranium is a radiotoxic element found in trace quantities in alomost all natural accurring materials like soil, rock. Radon an inert radioactive gas whose predecessor in uranium, is emitted from soil beneath the house and from building materials. Accurate knowledge of exhalation rate plays an important role in characterization of the radon source strength in some building mat...