Long-term performance of transvenous, steroid-eluting, high impedance, passive-fixation ventricular pacing leads.
نویسندگان
چکیده
The long-term performance of two high impedance, steroid-eluting, passive-fixation ventricular leads, porous platinum iridium electrode CPI Selute Picotip 4035 (131 patients), and platinized platinum electrode Medtronic Capsure Z 5034 (57 patients), was compared with one conventional 8.0-mm2 porous platinum iridium electrode CPI Selute 4285 (38 patients). The mean follow-up period was 28 +/- 14 months. Capture threshold, R wave amplitude, and pacing impedance were measured at the time of implantation, immediately after implantation, 1 week, 1, 3, and 6 months after implantation and then every 6 months thereafter. The two high impedance leads revealed a higher sensing slew rate than the conventional lead, the R wave amplitude was similar among the three groups, but the voltage threshold at 0.5-ms pulse width was significantly higher in porous platinum iridium groups at the time of implantation. During follow-up, the conventional lead revealed a significantly higher R wave amplitude within the first 3 months, however, this pattern disappeared after 3 months. Pacing impedance was significantly higher in the high impedance porous platinum iridium electrode groups. Voltage threshold at 0.5-ms pulse width was similar among the three groups in the first 3 months, however, it increased gradually and was significantly higher in porous platinum iridium electrode groups subsequently. The energy threshold at 0.5 ms was significantly lower in the two high impedance groups than the conventional group, but no difference was found in the two high impedance groups. Lead related complications were similar among the three groups. In conclusion, high impedance electrodes with different design and materials had different properties; platinized platinum electrode showed a lower pacing impedance but had a more stable long-term capture threshold as compared to the porous platinum iridium electrode. Further studies are mandatory for the development of an ideal pacing lead.
منابع مشابه
Comparison of mid-term clinical experience with steroid-eluting active and passive fixation ventricular electrodes in children.
Although active fixation ventricular leads seem to have advantages over passive fixation leads, this study compares the follow-up results of active and passive fixation leads in children. We evaluated the implantation and follow-up data of 41 children with active (Accufix II DEC, group 1) (n = 20) or passive (Membrane E, group 2) (n = 21) fixation, steroid-eluting ventricular leads. All but one...
متن کاملEpicardial left ventricular leads via minimally invasive technique: a role of steroid eluting leads
BACKGROUND We retrospectively assessed two types of sutureless screw-in left ventricular (LV) leads (steroid eluting vs. non-steroid eluting) in cardiac resynchronization therapy (CRT) implantation with regards to their electrical performance. METHODS Between March 2008 and May 2014 an epicardial LV lead was implanted in 32 patients after failed transvenous LV lead placement using a left-side...
متن کاملA long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads
Active-fixation pacing leads allow the use of selective pacing sites. We evaluated their long-term performance versus passive-fixation leads in 199 newly implanted patients (n = 100 active and n = 99 passive). Postoperative pacing thresholds in the active group were higher than in the passive group (0.85 ± 0.31 V vs. 0.53 ± 0.21 V at baseline, P < 0.001). The active thresholds fell to 0.72 ± 0....
متن کاملEndocardial and epicardial steroid lead pacing in the neonatal and paediatric age group.
AIM To compare the performance of steroid eluting epicardial and endocardial leads in infants and children requiring permanent pacing. METHODS Evaluation of pacing and sensing characteristics, impedances, and longevity of 159 steroid eluting leads implanted in 95 children. Group A consisted of 24 children weighing less than 15 kg with 15 endocardial leads (five atrial, 10 ventricular) and 19 ...
متن کاملLong term transvenous ventricular pacing in adults with congenital abnormalities of the heart and great arteries.
Improved techniques of transvenous pacing have made it possible to use this approach in various congenital cardiac abnormalities. Transvenous active fixation pacing leads were implanted in seven patients aged 15 to 81 years with abnormal venous, atrioventricular, or ventriculoarterial connections with successful ventricular pacing.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 27 10 شماره
صفحات -
تاریخ انتشار 2004