Dual-tuned 1h/13c Orthogonal Double Solenoid Volume Coil for Simultaneous Acquisition in Small Animals in Vivo

نویسندگان

  • L. C. Bell
  • E. T. Peterson
  • J. W. Gordon
  • S. B. Fain
  • K. N. Kurpad
چکیده

Figure 2: Transverse signal profile acquired with rat H/C ODS coil with gradient echo using saline phantom. Figure 3: C imaging spectrum acquired with rat H/C ODS coil with peak at 163 ppm, line width = 14.1 Hz, and SNR = 112.7. Figure 4: An example of simultaneous acquisition in vivo of H and C-pyruvate in a 150-g rat using the dual-tuned ODS coil. The proton image is acquired at the same time point with the lactate (left) and pyruvate (right) signals. DUAL-TUNED 1H/13C ORTHOGONAL DOUBLE SOLENOID VOLUME COIL FOR SIMULTANEOUS ACQUISITION IN SMALL ANIMALS IN VIVO

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous 23Na/1H Imaging with Dual Excitation and Double Tuned Birdcage Coil

Introduction The tissue concentration of sodium is sensitive to disease as an indicator of cellular and metabolic integrity [1]. Due to the low 23Na MR signal level, however, relatively long scan times are required. Furthermore, an additional 1H image in needed for an anatomic co-registration. In this context, a truly simultaneous acquisition of the 23Na and 1H signal would be helpful to reduce...

متن کامل

1H and 23Na MRI of Rat Head at 4 Tesla with a Simple Double-Tuned RF Surface Coil

Introduction MRI is proving to be a very useful tool for sodium (23Na) quantification in animal models of stroke, ischemia, and cancer. To obtain co-registered anatomical (1H) and physiological (23Na) information a dual-frequency RF coil is required, and several designs of surface RF coils were previously reported [1-7]. Aims We present the practical design of a dual-frequency RF surface coil t...

متن کامل

In vivo absolute quantification for mouse muscle metabolites using an inductively coupled synthetic signal injection method and newly developed (1) H/(31) P dual tuned probe.

PURPOSE To obtain robust estimates of (31) P metabolite content in mouse skeletal muscles using our recently developed MR absolute quantification method and a custom-built (1) H/(31) P dual tuned radiofrequency (RF) coil optimized for mouse leg. MATERIALS AND METHODS We designed and fabricated a probe consisting of two dual tuned (1) H/(31) P solenoid coils: one leg was inserted to each solen...

متن کامل

Novel Orthogonal Double Solenoid (ODS) Volume RF Coil for Small Animal Imaging

Introduction: Solenoids are known to be inherently high SNR coils that also generate highly homogeneous radio frequency magnetic (B1) fields[1]. The traditional solenoidal coil generates B1 field that is parallel to the static magnetic (B0) field. Hence, solenoidal RF coils currently in use for small animal imaging are typically designed for large bore clinical scanners, where the RF coil may b...

متن کامل

Muscle group specific quantification of unsaturated fatty acids by localized DEPT-enhanced 13C MRS and ERETIC

Introduction 13C MR spectroscopy in vivo enables to obtain metabolic information of humans not easily obtained by other non-invasive methods. The large chemical shift range of 13C MR spectra allows the resolution of resonances from a large number of substances, and thereby the study of some metabolites which are difficult to resolve in 1H MRS. One of them are unsaturated fatty acids, whose conc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010