Low-cost Gel Imaging System Implementation in Reduced Size
نویسندگان
چکیده
In this paper, we proposed a method for configuring each component of a gel documentation system for the miniaturization and penetration of the system. To miniaturize the UV illuminator part, the minimum type of UVB lamp was adopted along with ballasts that can drive four lamps. As the imaging system, a conventional compact digital camera, which has a similar performance to that of a DSLR, was adopted. By developing and supplementing the PC remote control function of which lack in the low-end digital camera, the price and size of the gel doc equipment can be significantly reduced while still maintaining the performance and function of the gel doc. The proposed system showed comparable performance and image quality to those of the existing Gel documentation system even though if it was small and inexpensive.
منابع مشابه
Investigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملDevelopment of Low-cost Gel Imaging System
In this paper, we proposed a method for configuring each component of a gel documentation system for the miniaturization and penetration of the system. To miniaturize the UV illuminator part, the minimum type of UVB lamp was adopted along with ballasts that can drive four lights. As the imaging system, a conventional compact digital camera, which has a similar performance to that of a DSLR, was...
متن کاملSmall field size dose-profile measurements using MAGIC- f polymer gel dosimeter and EBT3 film dosimeter
Introduction: In radiotherapy, treatment planning methods are evaluating and transforming every day, so precision in calculation and determination of dose delivery process is performing more important role in radiotherapy than past. In modern radiotherapy treatments, deramatically increase of small fields utilization, causes the polymeric gels has known as the most reliable dos...
متن کاملEvaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter
Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...
متن کاملInvestigation of the Spatial Resolution of MR-Based Polymer Gel Dosimetry versus Film Densitometry using Dose Modulation Transfer Function
Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...
متن کامل