Software for Modelling Positron-Beam Depth-Profiling Data

نویسندگان

  • H. Schut
  • A. Van Veen
  • A. van Veen
چکیده

The fitting program VEPFIT has been extended with applications running under the Microsoft Windows environment facilitating the input and output of the VEPFIT fitting module. We have exploited the Microsoft-Windowsm graphical users interface by making use of dialog windows, scrollbars, command buttons etc. The user communicates with the program simply by clicking and dragging with the mouse pointing device. Keyboard actions are limited to a minimum. Upon changing one or more input parameters the results of the modeling of the S-parameter and Ps-fraction versus positron implantation energy are updated and displayed. This action can be considered as the first step in the fitting procedure upon which the user can decide to further adapt the input parameters or to forward these parameters as initial values to the fitting routine. The modeling step has proven to be hetpful for designing positron beam experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسۀ دو روش برهم‌کنش هسته‌ای و پراکندگی تشدیدی برای اندازه‏گیری نمایۀ عمقی اکسیژن در آلومینای نانو متخلخل

Depth profiling of Oxygen in the surface of materials is important for many oxide elements. In this research two methods of ion beam analysis techniques were used for depth profiling of oxygen in nanoporous anodic Alumina by Nuclear Reaction Analysis (NRA) ( 16O(d, p1)17O ,16O(d, p0)17O) and resonant elastic scattering (RES)( 16O(α, α)16O). By using simulation software, variation of oxygen conc...

متن کامل

Characterize Porous Materials

■ Abstract Beam-based positron annihilation spectroscopy (PAS) is a powerful porosimetry technique with broad applicability in the characterization of nanoporous thin films, especially insulators. Pore sizes and distributions in the 0.3–30 nm range are nondestructively determined with only the implantation of low-energy positrons from a table-top beam. Depth-profiling with PAS has proven to be ...

متن کامل

Impact of Silicone gel breast prosthesis on photon beam therapy of recurrence carcinoma post mastectomy

AbstractIntroduction Silicone gel breast implants are used for breast reconstruction post mastectomy. In the event of cancer recurrence, the radiation oncologists are forced to irradiate through the prosthesis device. Due to prosthesis higher atomic number dose perturbations occur during treatment. This study determined the influence of silicone gel thickness on the photon beam distribution. Ma...

متن کامل

Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

متن کامل

A Comparative Study of the Construction of Positron Emission Tomography/Computed Tomography Facilities in Three South African Hospitals

Introduction: Development of higher energy modalities such as positron emission tomography/computed tomography (PET/CT), has led to more complex shielding problems. This is due to several factors, such as the radiopharmaceutical relatively high-administered activity, high patient throughput, and high energies of 511 kilo-electron volt (keV) positron annihilation photon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016