BACKGROUND Upper cervical spine instability is one of the most critical orthopedic problems in patients with Down syndrome. However, arthrodesis of the upper cervical spine in these patients can be very difficult to achieve and has a high complication rate because of mental retardation and accompanying various medical conditions of the vital organs. Even now, surgeries in such patients, especially pediatric cases, are challenging and the optimal operative procedure remains unsettled. The purpose of this study was to report 2 cases of pediatric atlantoaxial instability due to Down syndrome in which posterior occipito-axial fixation with C2 laminar screws was performed. METHODS Case 1 was a girl aged 6 years 10 months who had atlantoaxial rotatory fixation with os odontoideum. Atlantoaxial rotatory fixation was incompletely reduced by halo traction, and it was not maintained without halo-ring and -vest fixation. Posterior occipito-axial fixation with bilateral C2 laminar screws was then performed. Case 2 was a boy aged 10 years 7 months who had atlantoaxial subluxation with os odontoideum. He also had incomplete quadriplegia, so he could neither walk nor have a meal by himself. Posterior occipito-axial fixation with right C2 pedicle and left C2 laminar screws was then carried out. RESULTS In case 1 bone union was obtained at 3 months after surgery and the patient's symptoms were resolved. In case 2 bone union was obtained at 3 months after surgery and the paralysis was improved. CONCLUSIONS/LEVEL OF EVIDENCE In cases of atlantoaxial instability due to Down syndrome, symptomatic patients often present between ages 5 and 15 years and mental retardation interferes with postoperative cervical immobilization. C2 laminar screws can be safely applied for the pediatric axis and biomechanically accomplished rigid fixation. The C2 laminar screw is one of the most useful options to achieve stability of the pediatric atlantoaxial complex without the risk of vertebral artery injuries (level IV case series).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability.

AIM In this study, we aimed at sharing our experiences and contributing to the literature by making a retrospective analysis of the patients we operated with screw-rod system for atlantoaxial instability in our clinic. MATERIAL AND METHODS Archive files of adult patients, who were operated for posterior C1-C2 stabilization with screw and rod in our clinic between January 2006 and January 2016...

متن کامل

A New Technique for the Surgical Treatment of Atlantoaxial Instability: C1 Lateral Mass and C2-3 Transfacet Screwing.

AIM Atlantoaxial instability is a special entity that may be caused by many disorders such as trauma, tumor, arthritis, congenital malformation and infection. Atlantoaxial fixation is needed to provide stability, prevent neurological deficits and correct deformity. The objective of this study is to introduce an alternative technique for the treatment of atlantoaxial instability in patients who ...

متن کامل

Posterior atlantal lateral mass fixation technique with polyaxial screw and rod fixation system.

OBJECTIVE Atlantoaxial instability may result from various pathologic conditions and operative treatment may be required to correct the deformity, provide stability and prevent neurological deficits. We presented our clinic's experience using C1-C2 fusion with polyaxial screw and rod fixation for C1 and C2 instability for various reasons. METHODS AND MATERIAL Four patients with atlantoaxial i...

متن کامل

Bilateral Pedicle and Crossed Translaminar Screws in C2

Multiple techniques exist for the fixation of C2, including axial pedicle screws and bilateral translaminar screws. We describe a novel method of incorporating both the translaminar and pedicle screws within C2 to improve fixation to the subaxial spine in patients requiring posterior cervical instrumentation for deformity correction or instability. We report three cases of patients with cervica...

متن کامل

C2–3 Fusion, C3–4 Cord Compression and C1–2 Posterior Facetal Instability: An Evaluation of Treatment Strategy Based on Four Surgically Treated Cases

STUDY DESIGN Four patients had C2-3 vertebral fusion and radiologically demonstrated cord compression at C3-4 level related to disc bulge with or without association of osteophytes and C1-2 posterior facetal dislocation. The outcome of treatment by atlantoaxial and subaxial facetal fixation is discussed. PURPOSE The article evaluates the significance of atlantoaxial facetal instability in cas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012