Tear film interferometry and corneal surface roughness.

نویسندگان

  • P Ewen King-Smith
  • Samuel H Kimball
  • Jason J Nichols
چکیده

PURPOSE Previous studies of optical interference from the whole thickness of the precorneal tear film showed much lower contrast than from the pre-contact lens tear film. It is hypothesized that the recorded low contrast is related to roughness of the corneal surface compared with the smooth contact lens surface. This hypothesis is tested, and characteristics of this roughness are studied. METHODS Reflectance spectra were recorded from 20 healthy individuals using a silicon-based sensor used in previous studies (wavelength range, 562-1030 nm) and an indium-gallium-arsenide (InGaAs) sensor responding at longer wavelengths (912-1712 nm). Interference from the whole thickness of the precorneal tear film caused oscillations in the reflectance spectra. RESULTS Spectral oscillations recorded with the InGaAs sensor were found to decay as a Gaussian function of wave number (1/wavelength). This is consistent with a rough corneal surface, whose distribution of surface height is also a Gaussian function. Contrast of spectral oscillations for the InGaAs sensor was, on average, approximately four times greater than that for the silicon sensor. CONCLUSIONS For the Gaussian roughness model based on InGaAs spectra, the corneal surface was characterized by a surface height SD of 0.129 μm. Spectral oscillations recorded with a silicon-based camera can have higher contrast than expected from this Gaussian roughness model, indicating some reflectance from a smoother or more compact surface. The results also indicate that InGaAs cameras could provide whole-thickness interference images of higher contrast than silicon-based cameras.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ocular surface changes in type II diabetic patients with proliferative diabetic retinopathy.

AIM To detect and analyze the changes on ocular surface and tear function in type II diabetic patients with proliferative diabetic retinopathy (PDR), an advanced stage of diabetic retinopathy (DR), using conventional ophthalmic tests and the high-resolution laser scanning confocal microscopy. METHODS Fifty-eight patients with type II diabetes were selected. Based on the diagnostic criteria an...

متن کامل

Effects of smoking on tear film and ocular surface.

This study was performed to evaluate the changes of tear film and ocular surface caused by smoking. Symptom scoring, tear film break-up time (BUT), basal tear secretion test, corneal sensitivity test, keratoepitheliopathy scoring, and conjunctival impression cytology were performed in 29 smokers (58 eyes) and 26 non-smokers (52 eyes). Tear film BUT, basal tear secretion, corneal sensitivity, an...

متن کامل

The challenge of dry eye diagnosis

The currently available methods for the diagnosis of dry eye are still far from being perfect for a variety of reasons. This review attempts to highlight the advantages and disadvantages of both traditional tests (such as Schirmer's test, break-up time and ocular surface staining) and innovative noninvasive procedures, including tear meniscus height measurement, corneal topography, functional v...

متن کامل

Dual interferometer for dynamic measurement of corneal topography.

The cornea is the anterior most surface of the eye and plays a critical role in vision. A thin fluid layer, the tear film, coats the outer surface of the cornea and serves to protect, nourish, and lubricate the cornea. At the same time, the tear film is responsible for creating a smooth continuous surface, where the majority of refraction takes place in the eye. A significant component of visio...

متن کامل

Tear film, contact lens, and patient factors associated with corneal staining.

PURPOSE The purpose of this study was to examine ocular surface and tear film, contact lens, care solution, medical, and patient-related factors that are associated with corneal staining in contact lens wearers. METHODS In this cross-sectional/nested case-control study, in addition to the assessment of corneal staining with fluorescein, a variety of tear film and ocular surface, contact lens,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2014