Functional rehabilitation with a foot plate modification for circular external fixation.

نویسندگان

  • James A Blair
  • Johnny G Owens
  • Joey Saucedo
  • Joseph R Hsu
چکیده

BACKGROUND Customized foot plates attached to the foot ring of an ankle-spanning circular external fixator present a unique opportunity for patients undergoing complex lower-extremity limb salvage to participate in highly advanced weight-bearing physical therapy. The purpose of this study was to identify the rehabilitation capabilities afforded by this external fixator modification. METHODS Surgical logs and radiographs were reviewed to identify all lower-extremity limb salvage patients from February 2008 to December 2010 treated with an ankle-spanning circular external fixator and a customized foot plate treated by the same orthopedic surgeon and enrolled in our institution's Return To Run clinical pathway. Medical records were reviewed to identify a series of exercises that each patient was able to perform. RESULTS Eleven patients were identified. All patients were treated by the same physical therapist. All 11 patients were able to bear full weight on their foot plates and perform regular and split squats. Six of 11 patients were able to ambulate unassisted, and 5 patients required a cane. All 11 patients could navigate stairs and use an elliptical and stair-stepping machine. Six of 11 patients could perform single-leg hack squats. Eight of 11 patients were able to perform double-leg shuttle jumps, although only 5 of 11 patients could perform single-leg shuttle jumps. Five of 11 patients were able to perform a single-leg balance. Only 1 patient was able to run on the foot plate. CONCLUSIONS Patients undergoing lower-extremity limb salvage with an ankle-spanning circular external fixator and a customized foot plate were able to participate in highly advanced weight-bearing physical therapy exercises during the osseous and soft-tissue healing process. LEVEL OF EVIDENCE Level IV, retrospective case series.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femoral locking plate failure salvaged with hexapod circular external fixation: a report of two cases

Femoral non-unions are difficult to treat even for the experienced orthopaedic trauma surgeon. If the non-union follows failure of modern stable internal fixation, the complexity of the management is further increased. We report two cases of stiff hypertrophic femoral non-unions after failed locking plate fixation that were successfully treated with a new hexapod circular external fixator. In a...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Anterior Ankle Arthrodesis with Molded Plate: Technique and Outcomes

Background:  There is still controversy regarding the best technique for ankle arthrodesis to acheive stable rigid fixation along with reconstructing a functional plantigrade foot. Moreover, existing techniques have complictions related to stability, soft tissue covering, fusion rate, and exposure. Methods: With the anterior approach exactly on the tibialis anterior sheath, the joint was expose...

متن کامل

Effect of Rocker Bar Ankle Foot Orthosis on Functional Mobility in Post-Stroke Hemiplegic Patients: Timed Up and Go and Gait Speed Assessments

Objectives: Ankle Foot Orthoses (AFOs) are widely utilized to improve walking ability in hemiplegic patients. The present study aimed to evaluate the effect of Rocker bar Ankle Foot Orthosis (RAFO) on functional mobility in post-stroke hemiplegic patients. Methods: Fifteen hemiplegic patients (men and women) who were at least 6-months poststroke and able to walk without an assis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle international

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 2013