Inflatable multichannel rectal applicator for adaptive image-guided endoluminal high-dose-rate rectal brachytherapy: design, dosimetric characteristics, and first clinical experiences
نویسندگان
چکیده
PURPOSE To investigate the dosimetric results and first clinical experiences with a new designed balloon applicator with adjustable catheters for endoluminal brachytherapy for patients with locally advanced rectal cancer not undergoing surgery. MATERIAL AND METHODS The applicator consists of an inflatable rectal balloon with six attached Foley catheters used as guidance for the inserted brachytherapy plastic needles. The construction of the applicator and the dosimetric profile in terms of representative dose points in 0, 2, 5, 10 mm ipsilaterally and in 0 mm contralaterally are described. The first clinical outcomes in three patients are reported. RESULTS For all three patients, a reproducible dose gradient was achieved. The surface dose on the target side was 204 ± 19% of the normalized dose in 5 mm (100%) tissue depth, and 143 ± 8% in 2 mm and 64 ± 3% in 10 mm tissue depth, while the surface dose on the contra-lateral side was 20 ± 8%. After radiochemotherapy with 50 Gy external beam radiotherapy and concomitant administration of capecitabine, a HDR brachytherapy boost in 2-3 fractions of 7-10 Gy each was delivered. All patients achieved a clinical complete response 3 month after the treatment, and no major toxicity was observed. CONCLUSION The use of the applicator was clinically feasible, and resulted in a stable and reproducible dose distribution. First clinical results are promising.
منابع مشابه
Advantages of inflatable multichannel endorectal applicator in the neo‐adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy
High-dose rate endorectal brachytherapy (HDR-EBT) is mainly used as a palliative treatment modality. In this paper, we compare dosimetry distributions for a single-channel catheter (Miami) applicator with distributions of the inflatable multichannel (Novi Sad) endorectal applicator. The comparisons were made with respect to dose coverage to the clinical tumor volume as well as to the bladder, r...
متن کاملDosimetric impacts of applicator displacements and applicator reconstruction-uncertainties on 3D image-guided brachytherapy for cervical cancer
PURPOSE To quantify the dosimetric impact of applicator displacements and applicator reconstruction-uncertainties through simulated planning studies of virtual applicator shifts. MATERIAL AND METHODS Twenty randomly selected high-dose-rate (HDR) titanium tandem-and-ovoid (T&O) plans were retrospectively studied. MRI-guided, conformal brachytherapy (MRIG-CBT) plans were retrospectively generat...
متن کاملSingle versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning
PURPOSE To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff ...
متن کاملبررسی دوز رکتوم و مقایسه دوزیمتری In-vivo با دوز بدست آمده از روش Planning در بیماران مبتلا به کارسینوم سرویکس و اندومتر که درمان براکیتراپی دریافت نمودهاند
Background & Aim: Genitalia system cancers are the third most common cancers. In females, surgery and/or radiotherapy±chemotherapy are treatments of choice for cervical, endometrial or vaginal cancers. Brachytherapy is a complementary part of External Beam Radiotherapy(EBRT). MDR(Medium Dose Rate) brachytherapy in female genitalia cancers is founded on two bases: high and appropriate dose d...
متن کاملStudy of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis
Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...
متن کامل