The correction factors for sucrose gap measurements and their practical applications.
نویسندگان
چکیده
The distribution of extracellular and intracellular potential in the sucrose gap apparatus, previously established for a single fiber using the cable equations for a core conductor model (Jirounek and Straub, Biophys. J., 11:1, 1971), is obtained for a multifiber preparation. The exact equation is derived relating the true membrane potential change to the measured potential differences across the sucrose gap, the junction potentials between sucrose and physiological solution, the membrane potential in the sucrose region, and the electrical parameters of the preparation in each region of the sucrose gap. The extracellular potential distribution has been measured using a modified sucrose gap apparatus for the frog sciatic nerve and the rabbit vagus nerve. The results indicate a hyperpolarization of the preparations in the sucrose region, of 60--75 mV. The hyperpolarization is independent of the presence of junction potentials. The calculation of the correction terms in the equation relating the actual to the measured potential change is illustrated for the case of complete depolarization by KC1 on one side of the sucrose gap. The correction terms in the equation are given for various experimental conditions, and a number of nomographic charts are presented, by means of which the correction factors can be rapidly evaluated.
منابع مشابه
Achievable accuracy in brain tumors by in vivo dosimetry with diode detectors
ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...
متن کاملIndependent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader
Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...
متن کاملتعیین ضرایب تصحیح تصاویر در تکنیک پانورامیک با استفاده از فانتوم فک پایین
Background and Aim: Image distortion is one of the major problems in panoramic radiography. Horizontal and vertical correction factors could be determined for more efficient clinical applications. The purpose of this study was to determine horizontal and vertical correction factors in panoramic radiography.Materials and Methods: In this test evaluation study in which an asymetric mandibular pha...
متن کاملEffect of Sucrose Replacement by Stevia as a Non-Nutritive Sweetener and Bulking Compounds on Physiochemical Properties of Foodstuffs
Background & Aim: Changes in lifestyle, decrease in physical exercise along with incidence of obesity, hypertension and cardiovascular diseases indicate a need for low calorie formulations. The sweetness of Stevia, a natural sweetener, is estimated to be 300 times as much as that of sugar. Extraction of stevia leaves is considered a promoter of calorie balance and a beneficial part of a healt...
متن کاملEffect of Sucrose Replacement by Stevia as a Non-Nutritive Sweetener and Bulking Compounds on Physiochemical Properties of Foodstuffs
Background & Aim: Changes in lifestyle, decrease in physical exercise along with incidence of obesity, hypertension and cardiovascular diseases indicate a need for low calorie formulations. The sweetness of Stevia, a natural sweetener, is estimated to be 300 times as much as that of sugar. Extraction of stevia leaves is considered a promoter of calorie balance and a beneficial part of a healt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biophysical journal
دوره 33 1 شماره
صفحات -
تاریخ انتشار 1981