Determination of inertial parameters using a dynamometer.

نویسندگان

  • Jongsang Son
  • Jeseong Ryu
  • Jungyoon Kim
  • Youngho Kim
چکیده

In this study, a simple method based on the dynamic equation of motion was introduced to determine the moment of inertia using a commercial dynamometer, and an optimization technique was utilized to estimate inertial parameters with the determined moment of inertia. To evaluate the feasibility of the developed method, three different passive speeds (i.e. 240, 270 and 300°/s) were chosen to confirm whether the moment of inertia values are the same irrespective of angular speeds. Moreover, the estimated inertial parameters (i.e., the mass, center of mass and moment of inertia) of the elbow attachment and the disk-like 3 kg-weight were compared with solutions of uniform square cube and solid disk, respectively. As a result, the values of moments of inertia of the elbow attachment were 0.216 ± 0.017, 0.215 ± 0.016 and 0.216 ± 0.017 kg · m(2) at angular speeds of 240, 270 and 300°/s, respectively. The values of the moment of inertia of both the attachment and weight were 0.821 ± 0.054, 0.823 ± 0.058 and 0.824 ± 0.053 kg · m(2) at angular speeds of 240, 270 and 300°/s, respectively. There were no significant differences among the speeds. The estimated inertial parameters of the attachment or the weight were very similar to the theoretical values. Therefore, it is expected that the developed method has the potential to estimate inertial parameters of a human body segment and to improve the accuracy and reliability of the studies on human dynamics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applications of Inertial Navigation Systems in Medical Engineering

Inertial navigation systems are of the most important and practical systems in determining the velocity, position and attitude of the vehicles and different equipment. In these systems, three accelerometers and three gyroscopes are used to measure linear accelerations and angular velocities of vehicles, respectively. By using the output of these sensors and special inertial algorithms in differ...

متن کامل

Evaluating the Effects of Dual Frequency Sonication Parameters on Acoustic Cavitation by Chemical Dosimeter Using Iodide

Background and Aims: Production of acoustic cavitation by sonication has been recently recommended as a targeted treatment. The experimental results from studies indicate that the activity of cavitation generated by bi- or multi-frequency ultrasound irradiation is higher than that caused by single frequency irradiation. In this study, effects dual (1 MHz and 40 kHz) and single frequency soni...

متن کامل

Ambulatory assessment of shoulder abduction strength curve using a single wearable inertial sensor.

The aim of the present article was to assess the reliability of strength curves as determined from tridimensional linear accelerations and angular velocities measured by a single inertial measurement unit (IMU) fixed on the upper arm during a shoulder abduction movement performed holding a 1 kg dumbbell in the hand. Within-subject repeatability of the task was assessed on 45 subjects performing...

متن کامل

همکاری رباتها در جابجایی جسم نامعین توسط کنترلر امپدانسچندگانه

Parameter identification techniques are particularly attractive to determine the inertial parameters of robot manipulators and manipulated payloads. These parameters are particularly needed in implementation of a model-based controller for robot manipulators. In this paper, the inertial parameters of a manipulated rigid-body object have been estimated. The Newton-Euler equations will be employe...

متن کامل

Determination of the Moment of Inertia of Limb Segment Using a Dynamometer

In this study, we introduced a simple method to determine the moment of inertia using a dynamometer. In order to evaluate the developed method, one male was required to test for his forearm including the hand on a dynamometer. In the process of finding moment of inertia, three different passive speeds, i.e. 240°/s, 270°/s, and 300°/s, were performed to confirm whether the calculated values at t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio-medical materials and engineering

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2014