Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration.

نویسندگان

  • A S Beddar
  • T R Mackie
  • F H Attix
چکیده

A minimally perturbing plastic scintillation detector has been developed for the dosimetry of high-energy beams in radiotherapy. The detector system consists of two identical parallel sets of radiation-resistant optical fibre bundles, each connected to independent photomultiplier tubes (PMTs). One fibre bundle is connected to a miniature water equivalent plastic scintillator and so scintillation as well as Cerenkov light generated in the fibres is detected at its PMT. The other 'background' bundle is not connected to the scintillator and so only Cerenkov light is detected by its PMT. The background signal is subtracted to yield only the signal from the scintillator. The water-equivalence of plastic scintillation detectors is studied for photon and electron beams in the radiotherapy range. Application of Burlin cavity theory shows that the energy dependence of such detectors is expected to be better than the commonly used systems (ionization chambers, LiF thermoluminescent dosimeters, film and Si diodes). It is also shown that they are not affected by temperature variations and exhibit much less radiation damage than either photon or electron diode detectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements.

The properties of a new scintillation detector system for use in dosimetry of high-energy beams in radiotherapy have been measured. The most important properties of these detectors are their hgh spatial resolution and their nearly water-equivalence. Measurements have shown that they have excellent reproducibility and stability, and a linear response versus dose-rate. It is also shown that they ...

متن کامل

Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy.

While scintillation dosimetry has been around for decades, the need for a dosimeter tailored to the reality of modern radiation therapy-in particular a real-time, water-equivalent, energy-independent dosimeter with high spatial resolution-has generated renewed interest in scintillators over the last 10 years. With the advent of at least one commercial plastic scintillation dosimeter and the eve...

متن کامل

Time‐resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification

PURPOSE Our group previously introduced an in vivo proton range verification methodology in which a silicon diode array system is used to correlate the dose rate profile per range modulation wheel cycle of the detector signal to the water-equivalent path length (WEPL) for passively scattered proton beam delivery. The implementation of this system requires a set of calibration data to establish ...

متن کامل

Experimental fragmentation studies with 12C therapy beams.

High-energy beams of (12)C ions in the range of 80-430 MeV u(-1) delivered by the heavy-ion synchrotron SIS-18 are used for radiotherapy of deep-seated localized tumors at the treatment unit at GSI Darmstadt. In order to improve the physical database, the fragmentation characteristics along the penetration path in tissue were investigated experimentally by using a water phantom as tissue-equiva...

متن کامل

Monte Carlo‐based beam quality and phantom scatter corrections for solid‐state detectors in 60Co and 192Ir brachytherapy dosimetry

Beam quality correction, kQQ0(r), for solid-state detectors diamond, LiF, Li2B4O7, Al2O3, and plastic scintillator are calculated as a function of distance, r, along the transverse axis of the 60Co and 192Ir brachytherapy sources using the Monte Carlo- based EGSnrc code system. This study also includes calculation of detector-specific phantom scatter correction, kphan(r), for solid phantoms suc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 37 10  شماره 

صفحات  -

تاریخ انتشار 1992