Is scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) quantitative?

نویسندگان

  • Dale E Newbury
  • Nicholas W M Ritchie
چکیده

Scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) is a widely applied elemental microanalysis method capable of identifying and quantifying all elements in the periodic table except H, He, and Li. By following the "k-ratio" (unknown/standard) measurement protocol development for electron-excited wavelength dispersive spectrometry (WDS), SEM/EDS can achieve accuracy and precision equivalent to WDS and at substantially lower electron dose, even when severe X-ray peak overlaps occur, provided sufficient counts are recorded. Achieving this level of performance is now much more practical with the advent of the high-throughput silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS). However, three measurement issues continue to diminish the impact of SEM/EDS: (1) In the qualitative analysis (i.e., element identification) that must precede quantitative analysis, at least some current and many legacy software systems are vulnerable to occasional misidentification of major constituent peaks, with the frequency of misidentifications rising significantly for minor and trace constituents. (2) The use of standardless analysis, which is subject to much broader systematic errors, leads to quantitative results that, while useful, do not have sufficient accuracy to solve critical problems, e.g. determining the formula of a compound. (3) EDS spectrometers have such a large volume of acceptance that apparently credible spectra can be obtained from specimens with complex topography that introduce uncontrolled geometric factors that modify X-ray generation and propagation, resulting in very large systematic errors, often a factor of ten or more.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra High Solid Angle EDS System Advanced STEM Analysis for FE-SEM

EDS (Energy dispersive X-ray spectrometry) is a technique used for elemental analysis of a sample, through detection of characteristic X-rays generated from a sample impacted by an electron beam. STEM (Scanning Transmission Electron Microscopy) is a method to obtain high spatial resolution images with Z-contrast [1]. STEM-in-SEM has recently become a technique of choice for high spatial resolut...

متن کامل

Interactive Analysis of Terabyte-sized SEM-EDS Hyperspectral Images

Scanning electron microscopy with energy-dispersive X-ray spectrometry (SEM-EDS) was used to characterize a macroscopic artifact from Peru (a Moche cast figure) [1]. A 3D hyperspectral datacube was acquired over 51.2 hours, measuring 11,520 x 9,984 pixels with 2,048 energy channels per pixel; each pixel corresponds to 900 nm in the x and y dimensions. With current technology, interacting with t...

متن کامل

Non-lithographic Fabrication of Ni-se Heterojunction Nanowires and their Electrical Characterization

In this paper, heterojunction nanowires of Ni-Se are fabricated via template-assisted electrodeposition process. Nanowires are characterized by scanning electron microscopy (SEM), Energy dispersive X-Ray Spectroscopy (EDS), X-ray diffractometry and electrical transport studies. SEM photographs reveal the uniform and dense growth of Ni-Se nanowires. X-ray diffraction pattern shows the crystallin...

متن کامل

Performing elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy-dispersive X-ray spectrometry (SEM/SDD-EDS).

Electron-excited X-ray microanalysis performed in the scanning electron microscope with energy-dispersive X-ray spectrometry (EDS) is a core technique for characterization of the microstructure of materials. The recent advances in EDS performance with the silicon drift detector (SDD) enable accuracy and precision equivalent to that of the high spectral resolution wavelength-dispersive spectrome...

متن کامل

Growth and Characterization of Iron Nanowires Into Anodized Aluminum Oxide Templates Using Electrodeposition Technique

The Fe nanowires were prepared by Ac electrodeposition method. The two steps anodized aluminum oxides (alumina) were used as templates for electrodeposition of magnetic nanowires. Sulfuric acid was used to anodize aluminum. The pours diameter and growth rate of alumina were investigated. The FeSO4 electrolyte was used for growth of nanowires. The prepared magnetic nanowires were characterized b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Scanning

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 2013