Effects of the Clarion Electrode Positioning System on auditory thresholds and comfortable loudness levels in pediatric patients with cochlear implants.

نویسندگان

  • G S Donaldson
  • M D Peters
  • M R Ellis
  • B J Friedman
  • S C Levine
  • F L Rimell
چکیده

OBJECTIVE To evaluate the effects of using the Electrode Positioning System on psychophysical auditory thresholds, most comfortable loudness levels, and electric auditory brainstem response (EABR) thresholds in children with the Clarion version 1.2 cochlear implant. DESIGN Retrospective analysis. SETTING Academic tertiary care center. PATIENTS AND METHODS Clinical records of a series of 25 children who received the Clarion version 1.2 cochlear implant at the University of Minnesota, Minneapolis, between January 1997 and August 1999 were examined. Measures evaluated were psychophysical thresholds (T-levels) and most comfortable loudness levels (M-levels) obtained at the 3-month posthookup audiologic evaluation and EABR thresholds obtained during implant surgery. Relevant threshold measures were available for 24 patients, 11 of whom had received the Clarion spiral electrode and electrode positioner (EP group) and 13 of whom had received the spiral electrode without positioner (non-EP group). The 3 measures (T-levels, M-levels, and EABR thresholds) were compared across groups. In addition, EABR thresholds were compared with T-levels and M-levels within groups. RESULTS Mean T-levels and M-levels were significantly lower for the EP group than for the non-EP group, and interpatient variability for these measures was considerably smaller in the EP group. Electric auditory brainstem response thresholds were not significantly different for EP vs non-EP patients; however, EABR data were available for only a few non-EP patients. CONCLUSIONS Use of the electrode positioner results in lower T-levels and M-levels in children with the Clarion version 1.2 cochlear implant, consistent with results of previous studies in adults, and reduces across-patient variability for these measures. It is unclear from the present data whether use of the electrode positioner systematically reduces intraoperative EABR thresholds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intensity coding in electric hearing: effects of electrode configurations and stimulation waveforms.

OBJECTIVES Current cochlear implants typically stimulate the auditory nerve with biphasic pulses and monopolar electrode configurations. Tripolar stimulation can increase spatial selectivity and potentially improve place pitch related perception but requires higher current levels to elicit the same loudness as monopolar stimulation. The present study combined delayed pseudomonophonasic pulses, ...

متن کامل

Radiologic and functional evaluation of electrode dislocation from the scala tympani to the scala vestibuli in patients with cochlear implants.

BACKGROUND AND PURPOSE Localization of the electrode after cochlear implantation seems to have an impact on auditory outcome, and conebeam CT has emerged as a reliable method for visualizing the electrode array position within the cochlea. The aim of this retrospective study was to evaluate the frequency and clinical impact of scalar dislocation of various electrodes and surgical approaches and...

متن کامل

Effects of electrode configuration on cochlear implant modulation detection thresholds.

Cochlear implant function, as assessed by psychophysical measures, varies from one stimulation site to another within a patient's cochlea. This suggests that patient performance might be improved by selection of the best-functioning sites for the processor map. In evaluating stimulation sites for such a strategy, electrode configuration is an important variable. Variation across stimulation sit...

متن کامل

Radiological and Histological Evaluation of Perimodular Electrodes: Impact on Cochlear Implant Development

Introduction: Different Perimodiolar electrodes were developed by many cochlear implant (CI) manufacturers in the past few years. Possible advantages are lower stimulation thresholds and a better channel separation. A position close to the modiolus can be facilitated by different means: preformed electrode shape (Nucleus ContourTM electrode, Cochlear Corp., Australia), additional positioning el...

متن کامل

Neurophysiology of cochlear implant users II: comparison among speech perception, dynamic range, and physiological measures.

OBJECTIVE The overall objective of this study was to relate electrically evoked potentials recorded from different levels of the auditory pathway with behavioral measures obtained from adult cochlear implant subjects. The hypothesis was that adult recipients of cochlear implants who have open-set speech perception and those recipients with no open-set speech perception would differ in their neu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of otolaryngology--head & neck surgery

دوره 127 8  شماره 

صفحات  -

تاریخ انتشار 2001