Correction for field nonuniformity in scintillation cameras through removal of spastial distortion.

نویسندگان

  • G Muehllehner
  • J G Colsher
  • E W Stoub
چکیده

A method to correct for the spatial distortions of gamma cameras has been developed. The method consists of two parts: measuring spatial distortions and repositioning events during accumulation. Distortions are measured using a pattern consisting of parallel slits on 15-mm centers with slit-pattern images obtained in two orthogonal orientations. Slit locations are used to determine X and Y displacements. In repositioning camera events, X and Y event coordinates are digitized and correction displacements added. The procedure is implemented in hardware that replositions each event in real time without introducing additional dead time. Distortion removal offers considerable advantage over other uniformity-improvement schemes, since it correctly compensates for the major cause of nonuniformity, spatial distortion. The method may be used for quantitative studies, because it does not change the number of detected events.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Influence of Scintillation on Quality of Ozone Monitoring by Gomos

Point-like nature of stars leads to significant disturbances of light beams passed through the atmosphere by refractive effects. These effects should be taken into account in retrievals from stellar occultation measurements. We consider the influence of scintillation on stellar occultation measurements and on quality of ozone retrievals from these measurements, based on experience of the GOMOS ...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

Method for Increasing Apparent Amplitude Resolution, and Correcting Luminance Nonuniformity in Projected Displays

Projectors suffer from nonuniformity across the display, as well as spurious contours due to insufficient levels. This work offers an efficient and accurate solution to both problems. A camera-based calibration scheme both measures the spatial luminance nonuniformity and detects the projected levels that are unique. Using this data, an attenuation array is built using reverse-3D-table lookup. T...

متن کامل

A RLS Filter for Nonuniformity and Ghosting Correction of Infrared Image Sequences

In this paper, a technique to improve the convergence and to reduce the ghosting artifacts of a previously developed adaptive scenebased nonuniformity correction method is presented. The nonuniformity correction method estimates detector parameters based on the recursive least square filter approach. We propose, three parameters to reduce ghosting artifacts and to speed up the convergence of su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 21 8  شماره 

صفحات  -

تاریخ انتشار 1980