Ten Years Experience with Noncemented Revision Sockets
نویسنده
چکیده
replacement cases were followed-up a mean of reported that 70 % of the revisions of the acetabular 4.3 years (2 to 9.8 years). Of the 167 cases, 28 component that had been performed with cement in hips had a bulk structural allograft and 139 hips their series were associated with progressive had a rim fit. Of the 139 rim fit acetabular radiolucency. Revision arthroplasty using cemented components, 70 hips had slurry bone graft; 69 acetabular components with allograft has not given had no bone graft. Harris hip scores were used encouraging results either. 7, 8 Graft resorption and
منابع مشابه
Clinical and roentgenographic evaluation of bipolar prostheses with noncemented anatomic medullary locking femoral stems.
Fifty-six DePuy anatomic medullary locking femoral bipolar prostheses were reviewed clinically and roentgenographically in 50 patients at an average follow-up period of 30 months (range, 24-71 months). Forty-four of the implantations were in 40 male and 12 were in ten female patients. Forty-five devices were placed in primary operations, while 11 were used in revisions. The overall average age ...
متن کاملAnterior approach to total hip replacement: surgical technique and clinical results of our first one thousand cases using non-cemented prostheses.
Total hip replacement has evolved into one of the most frequently performed reconstructive procedures in orthopaedic surgery today. A modified anterior approach developed by the senior surgeon has been utilized in performing over 3,000 operations in the past two decades. It is a unique and facile exposure. It can be easily applied to primary and revision surgery. Noncemented prostheses have bee...
متن کاملResults of custom-fit, noncemented, semiconstrained total elbow arthroplasty for inflammatory arthritis at an average of eighteen years of follow-up.
BACKGROUND The literature available on the results after noncemented total elbow arthroplasty (TEA) in inflammatory arthritis is limited. METHODS Ten patients (7 women, 3 men; 14 elbows total) who underwent custom, noncemented TEA from 1988 to 1995 were retrospectively reviewed. The average age was 28 years (range, 17-45 years). Four patients (4 elbows) had rheumatoid arthritis, and 6 patient...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملEvora® chromium-cobalt dual mobility socket: results at a minimum 10 years' follow-up.
INTRODUCTION The Evora chromium-cobalt alloy dual mobility socket claims to display a large articulation tribology different from that of stainless steel models, limiting the risk of intraprosthetic dislocation and wear. The present study reports a minimum of 10years' follow-up in a multicenter prospective series of 200 sockets previously reported on at 5years. HYPOTHESIS The use of chromium-...
متن کامل