Partial and complete expulsion of the Multiload 375 IUD and the levonorgestrel-releasing IUD after correct insertion.

نویسندگان

  • Gabriele S Merki-Feld
  • Danielle Schwarz
  • B Imthurn
  • P J Keller
چکیده

OBJECTIVE The contraceptive efficacy of intrauterine devices (IUD) is thought to relate to the position of the IUD in the uterine cavity. Several trials examined the number of copper IUD expulsions, but none evaluated the partial and complete expulsion rate of the levonorgestrel-releasing device (LNG-IUD). STUDY DESIGN This retrospective cohort study compares the dislocation rate of the Multiload 375 IUD (ML 375) and the LNG-IUD in 214 women (107 subjects with each IUD). Transvaginal ultrasound was used to monitor the IUD position immediately after insertion, after 6 weeks, and later on at intervals of 6 months. The observation period included 3631 cycles. RESULTS We detected a significantly lower number of dislocations in LNG-IUD users. Previous expulsion was associated with a significantly higher risk for a re-expulsion in both IUD groups. Hypermenorrhea was not associated with an increased dislocation rate in LNG-IUD users. CONCLUSION Expulsions are less likely to occur with the LNG-IUD, which might contribute to its contraceptive efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of frameless intrauterine devices and systems in young nulliparous and adolescent women: results of a multicenter study

BACKGROUND The purpose of this study was to provide additional data on the experience with frameless copper and levonorgestrel (LNG) intrauterine devices (IUDs) in nulliparous and adolescent women. METHODS Nulliparous and adolescent women, 25 years of age or younger, using the frameless copper IUD or the frameless LNG-releasing intrauterine system (IUS), were selected from previous studies an...

متن کامل

Intrauterine devices: an update.

Three intrauterine devices (IUDs) are available in the United States: the copper T 380A and two levonorgestrel-releasing IUDs, one that releases 20 mcg of levonorgestrel per 24 hours, and one that releases 14 mcg per 24 hours. All are safe and effective methods of contraception that work predominantly by prefertilization mechanisms. The copper T 380A IUD may be placed in nonpregnant women at an...

متن کامل

Postplacental or delayed insertion of the levonorgestrel intrauterine device after vaginal delivery: a randomized controlled trial.

OBJECTIVE To estimate whether 6-month use of the levonorgestrel-releasing intrauterine device (IUD) would be higher when insertion occurred within 10 minutes of placental delivery compared with 6-8 weeks postpartum. METHODS We enrolled pregnant women planning vaginal deliveries and desiring a postpartum levonorgestrel-releasing IUD. Patients were randomly assigned when admitted in labor to po...

متن کامل

Intrauterine device insertion during the postpartum period: a systematic review.

BACKGROUND Insertion of an intrauterine device (IUD) at different times or by different routes during the postpartum period may increase the risk of complications. METHODS We searched Medline, Lilacs and Cochrane Collaboration databases for articles in any language, between database inception until December 2008, which compared outcomes of postpartum IUD insertion time intervals. Search terms...

متن کامل

Uterine perforation by the multiload CU250 intra-uterine device.

A case of perforation of the uterus by the Multiload Cu250 IUD in a 28 year old Malay woman is presented. The Multiload Cu250 is a newer device, introduced in 1974, and the mode of insertion (withdrawal) makes perforation with this IUD unlikely and to date no such case had been reported. The patient, para 3, had a period of amenorrhea of 7 weeks. A menstrual regulation procedure was performe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of obstetrics, gynecology, and reproductive biology

دوره 137 1  شماره 

صفحات  -

تاریخ انتشار 2008