Enhanced Vitreous Imaging in Healthy Eyes Using Swept Source Optical Coherence Tomography
نویسندگان
چکیده
PURPOSE To describe enhanced vitreous imaging for visualization of anatomic features and microstructures within the posterior vitreous and vitreoretinal interface in healthy eyes using swept-source optical coherence tomography (SS-OCT). The study hypothesis was that long-wavelength, high-speed, volumetric SS-OCT with software registration motion correction and vitreous window display or high-dynamic-range (HDR) display improves detection sensitivity of posterior vitreous and vitreoretinal features compared to standard OCT logarithmic scale display. DESIGN Observational prospective cross-sectional study. METHODS Multiple wide-field three-dimensional SS-OCT scans (500×500A-scans over 12×12 mm2) were obtained using a prototype instrument in 22 eyes of 22 healthy volunteers. A registration motion-correction algorithm was applied to compensate motion and generate a single volumetric dataset. Each volumetric dataset was displayed in three forms: (1) standard logarithmic scale display, enhanced vitreous imaging using (2) vitreous window display and (3) HDR display. Each dataset was reviewed independently by three readers to identify features of the posterior vitreous and vitreoretinal interface. Detection sensitivities for these features were measured for each display method. RESULTS Features observed included the bursa premacularis (BPM), area of Martegiani, Cloquet's/BPM septum, Bergmeister papilla, posterior cortical vitreous (hyaloid) detachment, papillomacular hyaloid detachment, hyaloid attachment to retinal vessel(s), and granular opacities within vitreous cortex, Cloquet's canal, and BPM. The detection sensitivity for these features was 75.0% (95%CI: 67.8%-81.1%) using standard logarithmic scale display, 80.6% (95%CI: 73.8%-86.0%) using HDR display, and 91.9% (95%CI: 86.6%-95.2%) using vitreous window display. CONCLUSIONS SS-OCT provides non-invasive, volumetric and measurable in vivo visualization of the anatomic microstructural features of the posterior vitreous and vitreoretinal interface. The vitreous window display provides the highest sensitivity for posterior vitreous and vitreoretinal interface analysis when compared to HDR and standard OCT logarithmic scale display. Enhanced vitreous imaging with SS-OCT may help assess the natural history and treatment response in vitreoretinal interface diseases.
منابع مشابه
Three-Dimensional Enhanced Imaging of Vitreoretinal Interface in Diabetic Retinopathy Using Swept-Source Optical Coherence Tomography.
PURPOSE To analyze the vitreoretinal interface in diabetic eyes using 3-dimensional wide-field volumes acquired using high-speed, long-wavelength swept-source optical coherence tomography (SSOCT). DESIGN Prospective cross-sectional study. METHODS Fifty-six diabetic patients (88 eyes) and 11 healthy nondiabetic controls (22 eyes) were recruited. Up to 8 SSOCT volumes were acquired for each e...
متن کاملAn Assessment of Vitreous Degeneration in Eyes with Vitreomacular Traction and Macular Holes
Purpose. To compare the stages of vitreous degeneration in patients with vitreomacular traction (VMT) and macular holes (MH). Methods. A retrospective study was performed analyzing stages of vitreous degeneration of eyes with VMT or MH using swept-source optical coherence tomography (SS-OCT) and spectral-domain optical coherence tomography (SD-OCT). An analogous review was performed on a contro...
متن کاملObservation of posterior precortical vitreous pocket using swept-source optical coherence tomography.
PURPOSE To observe posterior precortical vitreous pockets (PPVPs) using swept-source optical coherence tomography (SS-OCT). METHODS We performed SS-OCT in both eyes of 58 volunteers (36 men, 22 women) using 12-mm horizontal vertical scans through the macula and optic disc. To minimize age-related changes (liquefaction or posterior vitreous detachment), all subjects were a mean of 26.2 years (...
متن کاملThe premacular bursa's shape revealed in vivo by swept-source optical coherence tomography.
OBJECTIVE To resolve the controversy surrounding the shape and relationship of posterior vitreous spaces by characterizing the connections between the premacular bursa, the area of Martegiani, and Cloquet's canal. DESIGN Comprehensive posterior vitreous maps were created using swept-source optical coherence tomography (SS OCT) in a cross-sectional study. PARTICIPANTS The posterior vitreous ...
متن کاملImaging of the Lamina Cribrosa using Swept-Source Optical Coherence Tomography.
The lamina cribrosa (LC) is the presumed site of axonal injury in glaucoma. Its deformation has been suggested to contribute to optic neuropathy by impeding axoplasmic flow within the optic nerve fibers, leading to apoptosis of retinal ganglion cells. To visualize the LC in vivo, optical coherence tomography (OCT) has been applied. Spectral domain (SD)-OCT, used in conjunction with recently int...
متن کامل