Estimates of arterial PCO2 and their effect on the calculated values of cardiac output and dead space on exercise.
نویسندگان
چکیده
1 . A study of exercise physiology in 117 children aged 6-16 is described including the measurement of cardiac output by the Indirect (CO,) Fick Principle. 2. Computer produced graphs enabled various alternative values for arterial Pco, (Pa,co,) to be inserted simultaneously into the Fick equation for cardiac output and the Bohr equation for dead space. 3. Dead space could be estimated with reasonable accuracy using end-tidal Pco,. 4. Cardiac output determination was unreliable at rest due to the small venoarterial Pco, difference but it was very good on exercise when this difference is much larger. 5. The Pa,co, used for the calculation of cardiac output could be derived either from ear lobe Pco, or end-tidal Pco,. However, the best estimate of cardiac output was that using the Pa,co, implied by assuming a normal dead space.
منابع مشابه
Causes of a high physiological dead space in critically ill patients
Since around 1950, physiological dead space - the difference between arterial and mixed expired pCO2 (partial pressure of carbon dioxide) divided by the arterial pCO2 - has been a useful clinical parameter of pulmonary gas exchange. In the previous issue of Critical Care, Niklason and colleagues remind us that physiological dead space, while easily measured, consolidates potentially very comple...
متن کاملThe Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)
Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...
متن کاملEffect of Endurance, Resistance and Concurrent training on the Function of the cardiac of healthy middle-aged women
Background & Aim: Cardiac functional adaptations are affected by gender, age, intensity and type of exercise. The aim of this study was to compare the effect of endurance, resistance, concurrent training on the cardiac function. Methods: Forty healthy middle-aged women (mean age 44/62±3/45 years, height 157/75±4/87 cm and weight 73/27±10/64 kg) were randomly divided into four groups (10 person...
متن کاملConduction and Dead-Time Voltage Drops Estimation of Asymmetric Cascaded H-Bridge Converters Utilizing Level-Shifted PWM Scheme
Linear AC power supplies can be replaced by their nonlinear switching counterparts due to the lower voltage drops and higher efficiency and power density of switching-mode inverters. Multilevel cascaded H-bridge (CHB) converters are the preferred inverter structure because of modular configuration, control, and protection. The output voltage quality in CHB converters depends on the number of ou...
متن کاملEstimated vs actual values for dead space/tidal volume ratios during incremental exercise in patients evaluated for dyspnea.
The physiologic dead space/tidal volume ratio (VD/VT) at rest and during exercise is a sensitive measurement of gas exchange that reflects matching of ventilation to perfusion, but requires an invasive measurement for its calculation. Determining VD/VT noninvasively uses estimations of arterial PCO2 based on the end-tidal PCO2. To further standardize incremental cardiopulmonary exercise testing...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 39 4 شماره
صفحات -
تاریخ انتشار 1970