Design changes in continuous-flow left ventricular assist devices and life-threatening pump malfunctions.

نویسندگان

  • Sajjad Soltani
  • Friedrich Kaufmann
  • Juliane Vierecke
  • Alexandra Kretzschmar
  • Ewald Hennig
  • Julia Stein
  • Roland Hetzer
  • Thomas Krabatsch
  • Evgenij V Potapov
چکیده

OBJECTIVES The implantable continuous-flow left ventricular assist devices (LVADs) HeartMate II (HM II) and HeartWare HVAD (HW) underwent design modifications. The impact of these changes on life-threatening pump malfunctions was evaluated. METHODS We retrospectively analysed pump malfunctions due to thrombosis or cable damage in patients supported with primarily implanted HM II (n = 191) and HW (n = 347), separated into patients supported with the old and new pump designs. In 2010, the cable strain relief of the HM II device was improved (132 patients with old and 79 with new) and sealed grafts were introduced (68 patients with sealed inflow connector and outflow graft and 125 without). In 2011, titanium sintering of the inflow cannula of HW pumps was introduced (137 patients with a non-sintered and 210 with a sintered inflow cannula). RESULTS The median support time was 1.12 (0-6.1) years for all HM II and 0.59 (0-4.2) years for all HW patients. The cumulative rate of events per patient-year (EPPY) was 0.11 in HM II patients, compared with 0.09 EPPY in HW patients (P = 0.32). After introduction of the new cable design, incidence of cable damage in HM II patients dropped from 0.06 to 0 EPPY (P = 0.03), whereas pump thrombosis increased from 0.02 to 0.14 EPPY (P < 0.001) after the sealed graft was introduced. Pump thrombosis occurred in 4% of patients supported with HW with a sintered inflow cannula vs 15% with a non-sintered pump; the incidence changed from 0.10 to 0.07 EPPY in sintered pumps (P = 0.45). Kaplan-Meier analysis showed no differences over a period of 2.5 years for events when the HM II cohort with sealed graft and new cable design (n = 68) was compared with the HW group with a sintered cannula (P = 0.14). CONCLUSIONS The modified cable strain relief of the HM II pump and the sintering of the inflow cannula of the HW pump demonstrated a significant reduction in the incidence of life-threatening pump-related complications, whereas the sealed inflow connector and outflow graft seem to be associated with a higher incidence of pump thrombosis. However, the overall incidence of pump-related complications after the latest design changes was similar for both pumps over a 2.5-year period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

The Unique Blood Pressures and Pulsatility of LVAD Patients: Current Challenges and Future Opportunities

An increasing number of end-stage heart failure patients are now implanted with continuous-flow left ventricular assist devices (CF-LVADs). Although this therapeutic approach is associated with improved clinical outcomes, continuous flow physiology reduces arterial pulse pressure and pulsatility to an extent that is unique to this population. Recent data suggest that high blood pressure (BP) co...

متن کامل

On Target

The use of mechanical circulatory support for patients with advanced heart failure has increased exponentially within the past 10 years. Durable left ventricular assist devices (LVADs) in particular have changed the treatment paradigm for medically refractory heart failure, with an evolution in patient selection from those tethered to the hospital bed with inotrope support as a bridge to transp...

متن کامل

Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.

BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...

متن کامل

Control Method of a Rotary Blood Pump for a Left Ventricular Assist Device

The aim of the investigation is to develop a control method of a rotary blood pump (RBP) to solve the following problems: estimation of the pump flow rate, achievement and maintaining of the desired flow level through the continuous adjustment of pump speed and prevention of adverse effects on the cardiovascular system. Results. Functional chart of RBP control consists of several units: a unit ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 47 6  شماره 

صفحات  -

تاریخ انتشار 2015